Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2019 Dec;30(12):2734-2742.
doi: 10.1111/jce.14220. Epub 2019 Oct 20.

Efficacy and safety of cryoballoon ablation for Chinese patients over 75 years old: A comparison with a younger cohort

Affiliations
Comparative Study

Efficacy and safety of cryoballoon ablation for Chinese patients over 75 years old: A comparison with a younger cohort

Jun Zhang et al. J Cardiovasc Electrophysiol. 2019 Dec.

Abstract

Introduction: Cryoballoon ablation (CBA) results in satisfactory outcomes for drug-resistant atrial fibrillation (AF) patients. However, the efficacy and safety of CBA have not yet been tested in the Chinese elderly population. Therefore, this study compared the recurrence of AF and complications of CBA in patients ≥75 years and <75 years.

Methods: A total of 677 patients (<75 years, n = 550; ≥ 75 years, n = 127) with paroxysmal (n = 603) or persistent (n = 74) non-valvular drug-resistant AF were included. The efficacy was assessed by the recurrence of AF, and the safety was evaluated by peri- and post-procedural complications.

Results: The CHA2DS2-VASc (2.6 ± 1.7 vs 4.8 ± 1.6, P < .01) and HAS-BLED (1.8 ± 0.8 vs 2.0 ± 0.8, P = .01) scores were significantly higher in the elderly group. The instant pulmonary vein isolation success rate was comparable (99.11% younger vs 98.98% older, P = .99). After a mean follow-up time of 12.8 ± 9.6 months, the 1-year freedom from AF rate was 80.6% vs 85.8% in the older and younger groups, respectively, while the survival analysis showed a nonsignificant difference in the rate of freedom from AF (log-rank P = .46). Cox regression showed that age was not a predictive factor for AF recurrence and was not dichotomized (hazard ratio [HR] = 0.868, 95% confidence interval [CI] 0.509-1.481; P = .6046) or continuous (HR = 0.990, 95% CI, 0.968-1.012, P = .3642). Similar complications rates were observed, including stroke (1.0% younger vs 0.93% older, P = .95) and major hemorrhagic events (1.2% younger vs 0% elder, P = .25).

Conclusions: The efficacy and safety profiles of CBA in patients older than 75 years are comparable with those in younger patients.

Keywords: Chinese; atrial fibrillation; cryoballoon ablation; efficacy; elderly population; safety.

PubMed Disclaimer

References

REFERENCES

    1. Chugh SS, Havmoeller R, Narayanan K, et al. Worldwide epidemiology of atrial fibrillation: a Global Burden of Disease 2010 Study. Circulation. 2014;129:837-847.
    1. Schnabel RB, Yin X, Gona P, et al. 50 year trends in atrial fibrillation prevalence, incidence, risk factors, and mortality in the Framingham Heart Study: a cohort study. Lancet. 2015;386:154-162.
    1. Zhang S. Atrial fibrillation in mainland China: epidemiology and current management. Heart. 2009;95:1052-1055.
    1. Haïssaguerre M, Jaïs P, Shah DC, et al. Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. N Engl J Med. 1998;339:659-666.
    1. Straube F, Dorwarth U, Ammar-Busch S, et al. First-line catheter ablation of paroxysmal atrial fibrillation: outcome of radiofrequency vs. cryoballoon pulmonary vein isolation. Europace. 2016;18:368-375.

Publication types

MeSH terms

LinkOut - more resources