Comparative Analysis of LASIK Flap Diameter and its Centration Using Two Different Femtosecond Lasers
- PMID: 31598523
- PMCID: PMC6778470
Comparative Analysis of LASIK Flap Diameter and its Centration Using Two Different Femtosecond Lasers
Abstract
The aim of this study was to compare the diameter, accuracy, variability, and centration with respect to the limbus of corneal flaps created by two femtosecond lasers, the VisuMax, and Wavelight FS200, for laser in situ keratomileusis (LASIK) and how these flaps affect visual outcomes. This is a retrospective chart review of flap morphology created during LASIK Surgery. Overall, 168 eyes underwent flap creation using the WaveLight FS200 laser, and on 189 eyes, the VisuMax laser was used. Of these total number, flap morphology was analyzed in a random sample of 158 eyes; 80 with the Visumax laser and 78 with the WaveLight FS200 laser. Intraoperative photos of the flaps taken by the Wavelight Allegretto EX500 were analyzed. Flap diameters and centration were measured using Adobe Acrobat Pro. All patients had visual acuity measurements including uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), spherical equivalent refraction (SE) and refractive astigmatism recorded three months postoperatively. Greater than 90% of patients in both groups achieved a UDVA of 20/20 postoperatively. The mean difference between targeted and achieved flap diameter was 0.50 +/- 0.15 mm in the VisuMax group and 0.35 +/- 0.15 millimeters (mm) in the FS200 group (P<0.01). The flap diameters of the VisuMax group were more precise with a variance of 0.024 mm compared to a variance of 0.038 mm in the FS200 group (P<0.05). VisuMax flaps were more nasally displaced (log(NA/TA) = -0.21 +/- 0.10 mm) compared to the FS200 flaps (log(NA/TA) = 0.03 +/- 0.10 mm), (P< 0.01). We concluded that both the VisuMax and FS200 created flaps larger than the preoperative targeted diameter. VisuMax created corneal flaps that had a greater degree of deviation from the targeted diameter when compared to flaps from the FS200. However, there was less variance in the VisuMax flap diameter. In addition, VisuMax flaps were more nasally displaced. There were no statistically significant differences in visual outcomes when comparing the two femtosecond lasers.
Keywords: Corneal Flap; Femtosecond Laser; Flap Centration; Flap Diameter; Flap Morphology; Flap Predictability; Flap Variance; Laser; Laser In Situ Keratomileusis; VisuMax Laser.
© 2019, Author(s).
Conflict of interest statement
Ethical issues have been completely observed by the authors. All named authors meet the International Committee of Medical Journal Editors (ICMJE) criteria for authorship of this manuscript, take responsibility for the integrity of the work as a whole, and have given final approval for the version to be published. No conflict of interest has been presented.
Figures
References
-
- Sugar A, Rapuano CJ, Culbertson WW, Huang D, Varley GA, Agapitos PJ, et al. Laser in situ keratomileusis for myopia and astigmatism: safety and efficacy: a report by the American Academy of Ophthalmology. Ophthalmology. 2002;109(1):175–87. - PubMed
-
- Varley GA, Huang D, Rapuano CJ, Schallhorn S, Boxer Wachler BS, Sugar A, et al. LASIK for hyperopia, hyperopic astigmatism, and mixed astigmatism: a report by the American Academy of Ophthalmology. Ophthalmology. 2004;111(8):1604–17. - PubMed
-
- Solomon KD, Fernandez de Castro LE, Sandoval HP, Biber JM, Groat B, Neff KD, et al. LASIK world literature review: quality of life and patient satisfaction. Ophthalmology. 2009;116(4):691–701. - PubMed
-
- McAlinden C. Corneal refractive surgery: past to present. Clin Exp Optom. 2012;95(4):386–98. - PubMed