Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Jan;128(1):17-28.
doi: 10.1002/cncy.22195. Epub 2019 Oct 10.

Diagnostic concordance between whole slide imaging and conventional light microscopy in cytopathology: A systematic review

Affiliations

Diagnostic concordance between whole slide imaging and conventional light microscopy in cytopathology: A systematic review

Ilaria Girolami et al. Cancer Cytopathol. 2020 Jan.

Abstract

Many studies have examined the diagnostic concordance of whole slide imaging (WSI) and light microscopy (LM) for surgical pathology. In cytopathology, WSI use has been more limited, mainly because of technical issues. The aim of this study was to review the literature and determine the overall diagnostic concordance of WSI and LM in cytopathology. A systematic search of PubMed, Scopus, and the Cochrane Library was performed, with data extracted from the included articles. A quality assessment of studies was performed with a modified Quality Assessment of Diagnostic Accuracy Studies 2 tool. The primary outcome was concordance for the diagnoses rendered by WSI and LM as shown by the concordance rate with the original diagnosis, intra-observer and interobserver concordance with the κ coefficient, or a percentage. Secondary outcomes included the time taken to reach a diagnosis and the quality and perception of WSI. A descriptive survey was provided. Among 1867 publications, a total of 19 studies (1%) were included. Overall, the concordance between WSI and the original diagnosis was 84.1%, the intra-observer concordance between WSI and LM was 92.5% with a κ coefficient of 0.66, and the interobserver κ coefficient was 0.69. The time to reach a diagnosis was longer with WSI in all studies. The quality of WSI was good, but diagnostic confidence and cytologist preference were higher for LM. In conclusion, the concordance of WSI with LM is acceptable and in line with systematic reviews in surgical pathology. However, the time required for scanning and technical issues represent barriers to complete adoption. It is foreseeable that technical advances and rigorous validation study design will help to improve the diagnostic concordance of WSI with LM in cytopathology.

Keywords: agreement; cytology; cytopathology; diagnostic concordance; review; whole slide imaging.

PubMed Disclaimer

References

    1. Park S, Pantanowitz L, Parwani AV. Digital imaging in pathology. Clin Lab Med. 2012;32:557-584. doi:10.1016/j.cll.2012.07.006
    1. Pantanowitz L, Wiley CA, Demetris A, et al. Experience with multimodality telepathology at the University of Pittsburgh Medical Center. J Pathol Inform. 2012;3:45. doi:10.4103/2153-3539.104907
    1. Pantanowitz L, Sinard JH, Henricks WH, et al. Validating whole slide imaging for diagnostic purposes in pathology: guideline from the College of American Pathologists Pathology and Laboratory Quality Center. Arch Pathol Lab Med. 2013;137:1710-1722. doi:10.5858/arpa.2013-0093-CP
    1. College of American Pathologists. Validating Whole Slide Imaging for Diagnostic Purposes in Pathology. Published 2019. Accessed July 28, 2019. https://www.cap.org/protocols-and-guidelines/cap-guidelines/current-cap-...
    1. Khalbuss WE, Pantanowitz L, Parwani AV. Digital imaging in cytopathology. Patholog Res Int. 2011;2011:264683. doi:10.4061/2011/264683

Publication types