Expert consensus statement for quantitative measurement and morphological assessment of optical coherence tomography
- PMID: 31602597
- DOI: 10.1007/s12928-019-00626-5
Expert consensus statement for quantitative measurement and morphological assessment of optical coherence tomography
Abstract
In this document, the methods for the quantitative measurement and morphological assessment of optical coherence tomography (OCT)/optical frequency domain imaging images (OFDI) are briefly summarized. The focus is on the clinical application of OCT/OFDI to guide percutaneous coronary interventions.
Keywords: Atherosclerosis; Coronary artery disease; Optical coherence tomography.