. 2019 Nov;144(5):e20190902.
doi: 10.1542/peds.2019-0902. Epub 2019 Oct 11.

Serum MMP-7 in the Diagnosis of Biliary Atresia

Affiliations

Serum MMP-7 in the Diagnosis of Biliary Atresia

Jingying Jiang et al. Pediatrics. 2019 Nov.

Abstract

Background: The overlapping features of biliary atresia (BA) and other neonatal cholestasis with alternative causes (non-BA) have posed challenges for diagnosis. Matrix metalloproteinase-7 (MMP-7) has been reported to be promising in diagnosing BA. We aimed to validate the diagnostic accuracy of MMP-7 for BA in a large population sample.

Methods: We enrolled 288 patients with neonatal obstructive jaundice from March 2017 to October 2018. Serum MMP-7 levels were measured by using an enzyme-linked immunosorbent assay. Receiver operating characteristic curves were constructed, and decision curve analysis was done. A Pearson correlation coefficient test was conducted to assess the correlation between MMP-7 levels and other characteristics.

Results: The median serum MMP-7 levels were 38.89 ng/mL (interquartile range: 22.96-56.46) for the BA group and 4.4 ng/mL (interquartile range: 2.73-6.56) for the non-BA group (P < .001). The area under the receiver operating characteristic curve value was 0.9829 for MMP-7, and the sensitivity, specificity, positive predictive value, and negative predictive value were 95.19%, 93.07%, 97.27%, and 91.43%, respectively, at a cutoff value of 10.37 ng/mL. When MMP-7 was combined with γ glutamyl transferase, the diagnostic accuracy was slightly improved without significance when compared with MMP-7 alone and had an area under the curve of 0.9880 (P = .08). Decision curve analysis also showed potential for MMP-7 to be used for clinical applications. A significant correlation was found with fibrosis stage from liver biopsy (R = 0.47; P < .001).

Conclusions: MMP-7 demonstrated good accuracy in diagnosing BA and holds promise for future clinical application. Furthermore, its correlation with liver fibrosis indicated its potential use as a therapeutic target or prognostic biomarker.