Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Feb 5:226:117644.
doi: 10.1016/j.saa.2019.117644. Epub 2019 Oct 9.

A novel label-free colorimetric aptasensor for sensitive determination of PSA biomarker using gold nanoparticles and a cationic polymer in human serum

Affiliations

A novel label-free colorimetric aptasensor for sensitive determination of PSA biomarker using gold nanoparticles and a cationic polymer in human serum

Omid Heydari Shayesteh et al. Spectrochim Acta A Mol Biomol Spectrosc. .

Abstract

In this colorimetric assay for sensitive detection of prostate specific antigen (PSA) tumor marker, adsorbed non-thiolated poly-Adenine aptamer (polyA Apt) on the gold nanoparticles (AuNPs) surface was used. By incubating the AuNPs and the PSA specific aptamer prior to target addition, polyA Apt adsorbed on the gold nanoparticles and could bind the target while preventing non-specific interactions. Adsorbed polyA Apt on the AuNPs prevents aggregation of them by poly(diallyldimethylammoniumchloride) (PDDA). Upon the addition of PSA, it bind to the polyA Apt and induce the formation of a secondary structure. Therefore, interaction between polyA Apt and PDDA is repressed and PDDA induce the aggregation of the AuNPs. This analytical platform produces a remarkable optical signal in the absence and presence of PSA that accompanied by a color change from red to blue. This effect as a sensing strategy can be observed with naked eyes and quantified by colorimetry via measurement of the ratio of absorbances at 680 nm and 520 nm. Fabricated aptasensor for detection of PSA is linear in the concentration range of 0.1-100 ng/ml with 20 pg/ml as the limit of detection (S/N = 3). Because of the selectively recognized for PSA in the presence of other interfering substances, this proposed assay applied to real samples for the rapid screening of PSA.

Keywords: Colorimetric aptasensor; Gold nanoparticles; PSA biomarker; PolyA aptamer.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources