Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Feb 8;153(3):342-345.
doi: 10.1093/ajcp/aqz164.

Rapid On-Site Evaluation With Telecytology Significantly Reduced Unsatisfactory Rates of Thyroid Fine-Needle Aspiration

Affiliations

Rapid On-Site Evaluation With Telecytology Significantly Reduced Unsatisfactory Rates of Thyroid Fine-Needle Aspiration

Diana M Lin et al. Am J Clin Pathol. .

Abstract

Objectives: We evaluated telecytology rapid on-site evaluation (ROSE) for thyroid ultrasound-guided fine-needle aspiration. To the best of our knowledge, this study is the first case-control clinical trial of thyroid telecytology.

Methods: We introduced on-site ROSE in our institution's thyroid clinic for 6 months, followed by telecytology for 12 months. Our institution's ultrasound clinic, where ROSE is not provided, was used as a control group for each period.

Results: Both groups had similar initial unsatisfactory rates (thyroid clinic: 8.8%; ultrasound clinic: 8.0%) before the study began. The thyroid clinic's unsatisfactory rate was significantly reduced to 1.6% after on-site ROSE (P = .001) and to 3.8% after telecytology ROSE (P = .010), with no significant difference between on-site and telecytology ROSE periods (P > .05). The ultrasound clinic's unsatisfactory rate was unchanged for both periods. Concordance between telecytology ROSE and final adequacy was 97% (κ = 0.699).

Conclusions: Telecytology ROSE reduces unsatisfactory rates for ultrasound-guided fine-needle aspiration without compromising patient care.

Keywords: Rapid on-site evaluation(ROSE); Telecytology; dequacy; hyroid; ine-needle aspiration.