Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2019 Nov 5;8(21):e012594.
doi: 10.1161/JAHA.119.012594. Epub 2019 Oct 23.

Pacemaker Implantation and Dependency After Transcatheter Aortic Valve Replacement in the REPRISE III Trial

Affiliations
Randomized Controlled Trial

Pacemaker Implantation and Dependency After Transcatheter Aortic Valve Replacement in the REPRISE III Trial

Christopher U Meduri et al. J Am Heart Assoc. .

Abstract

Background As transcatheter aortic valve replacement expands to younger and/or lower risk patients, the long-term consequences of permanent pacemaker implantation are a concern. Pacemaker dependency and impact have not been methodically assessed in transcatheter aortic valve replacement trials. We report the incidence and predictors of pacemaker implantation and pacemaker dependency after transcatheter aortic valve replacement with the Lotus valve. Methods and Results A total of 912 patients with high/extreme surgical risk and symptomatic aortic stenosis were randomized 2:1 (Lotus:CoreValve) in REPRISE III (The Repositionable Percutaneous Replacement of Stenotic Aortic Valve through Implantation of Lotus Valve System-Randomized Clinical Evaluation) trial. Systematic assessment of pacemaker dependency was pre-specified in the trial design. Pacemaker implantation within 30 days was more frequent with Lotus than CoreValve. By multivariable analysis, predictors of pacemaker implantation included baseline right bundle branch block and depth of implantation; diabetes mellitus was also a predictor with Lotus. No association between new pacemaker implantation and clinical outcomes was found. Pacemaker dependency was dynamic (30 days: 43%; 1 year: 50%) and not consistent for individual patients over time. Predictors of pacemaker dependency at 30 days included baseline right bundle branch block, female sex, and depth of implantation. No differences in mortality or stroke were found between patients who were pacemaker dependent or not at 30 days. Rehospitalization was higher in patients who were not pacemaker dependent versus patients without a pacemaker or those who were dependent. Conclusions Pacemaker implantation was not associated with adverse clinical outcomes. Most patients with a new pacemaker at 30 days were not dependent at 1 year. Mortality and stroke were similar between patients with or without pacemaker dependency and patients without a pacemaker. Clinical Trial Registration URL: https://www.clinicaltrials.gov/. Unique identifier NCT02202434.

Keywords: aortic valve stenosis; pacemaker dependency; permanent pacemaker; transcatheter aortic valve replacement.

PubMed Disclaimer

Figures

Figure 1
Figure 1
Patient flow and pacemaker indications. A, Patient flow. B, Other/unknown indications: 6 other, 5 left bundle branch block, 3 second degree atrioventricular block type 1 and 1 first degree atrioventricular block. AVB indicates atrioventricular block
Figure 2
Figure 2
Clinical impact of pacemaker implantation. A, all‐cause death, (B) cardiac death, (C) all stroke, and (D) hospitalization for valve‐related symptoms/worsening congestive heart failure (New York Heart Association class III/IV) in patients with a prior pacemaker at baseline (red), patients who did not receive a pacemaker (purple), and patients who received a pacemaker within 30 days of the index procedure (green). Event rates between 31 and 365 days were calculated with Kaplan–Meier methods. Error bars indicate standard error. AVB indicates atrioventricular block
Figure 3
Figure 3
Pacemaker dependency at 30 days and 1 year. A, Pacemaker status and dependency in patients who did not have a prior pacemaker at baseline. B, Change in pacemaker status and dependency between 30 days and 1 year.
Figure 4
Figure 4
Clinical impact of pacemaker dependency. A, All‐cause death, (B) cardiac death, (C) all stroke, and (D) hospitalization for valve‐related symptoms/worsening congestive heart failure (New York Heart Association class III/IV) in patients without a pacemaker at baseline (purple) and in patients who received a pacemaker within 30 days of the index procedure who were pacemaker dependent (orange) or not pacemaker dependent (blue) at 30 days. Event rates between 31 and 365 days were calculated with Kaplan–Meier methods. Error bars indicate standard error.

References

    1. Auffret V, Puri R, Urena M, Chamandi C, Rodriguez‐Gabella T, Philippon F, Rodés‐Cabau J. Conduction disturbances after transcatheter aortic valve replacement: current status and future perspectives. Circulation. 2017;136:1049–1069. - PubMed
    1. Siontis GC, Juni P, Pilgrim T, Stortecky S, Bullesfeld L, Meier B, Wenaweser P, Windecker S. Predictors of permanent pacemaker implantation in patients with severe aortic stenosis undergoing TAVR: a meta‐analysis. J Am Coll Cardiol. 2014;64:129–140. - PubMed
    1. Franzone A, Windecker S. The conundrum of permanent pacemaker implantation after transcatheter aortic valve implantation. Circ Cardiovasc Interv. 2017;10:e005514. - PubMed
    1. Feldman TE, Reardon MJ, Rajagopal V, Makkar RR, Bajwa TK, Kleiman NS, Linke A, Kereiakes DJ, Waksman R, Thourani VH, Stoler RC, Mishkel GJ, Rizik DG, Iyer VS, Gleason TG, Tchétché D, Rovin JD, Buchbinder M, Meredith IT, Götberg M, Bjursten H, Meduri C, Salinger MH, Allocco DJ, Dawkins KD. Effect of mechanically expanded vs self‐expanding transcatheter aortic valve replacement on mortality and major adverse clinical events in high‐risk patients with aortic stenosis: the REPRISE III randomized clinical trial. JAMA. 2018;319:27–37. - PMC - PubMed
    1. Kappetein AP, Head SJ, Genereux P, Piazza N, van Mieghem NM, Blackstone EH, Brott TG, Cohen DJ, Cutlip DE, van Es GA, Hahn RT, Kirtane AJ, Krucoff MW, Kodali S, Mack MJ, Mehran R, Rodes‐Cabau J, Vranckx P, Webb JG, Windecker S, Serruys PW, Leon MB. Updated standardized endpoint definitions for transcatheter aortic valve implantation: the valve academic research consortium‐2 consensus document. J Am Coll Cardiol. 2012;60:1438–1454. - PubMed

Publication types

Associated data