Impact of an electronic hard-stop clinical decision support tool to limit repeat Clostridioides difficile toxin enzyme immunoassay testing on test utilization
- PMID: 31647044
- PMCID: PMC7592157
- DOI: 10.1017/ice.2019.275
Impact of an electronic hard-stop clinical decision support tool to limit repeat Clostridioides difficile toxin enzyme immunoassay testing on test utilization
Abstract
We performed an intervention evaluating the impact of an electronic hard-stop clinical decision support tool on repeat Clostridioides difficile (CD) toxin enzyme immunoassay (T-EIA) testing. The CD testing rate and number of admissions with repeat tests decreased significantly postintervention (P < .01 for both); the percentage of positive tests was unchanged (P = .27).
References
-
- Manabe YC, Vinetz JM, Moore RD, Merz C, Charache P, Bartlett JG. Clostridium difficile colitis: an efficient clinical approach to diagnosis. Ann Intern Med 1995;123:835–840. - PubMed
-
- Peterson LR, Robicsek A. Does my patient have Clostridium difficile infection? Ann Intern Med 2009;151:176–179. - PubMed
-
- Stevens V, Dumyati G, Fine LS, Fisher SG, van Wijngaarden E. Cumulative antibiotic exposures over time and the risk of Clostridium difficile infection. Clin Infect Dis 2011;53:42–48. - PubMed
Publication types
MeSH terms
Grants and funding
LinkOut - more resources