. 2020 Feb;34(2):e4723.
doi: 10.1002/bmc.4723. Epub 2019 Dec 10.

Development and validation of an LC-MS/MS method for profiling 39 urinary steroids (estrogens, androgens, corticoids, and progestins)

Affiliations

Development and validation of an LC-MS/MS method for profiling 39 urinary steroids (estrogens, androgens, corticoids, and progestins)

Hyuck Ho Son et al. Biomed Chromatogr. 2020 Feb.

Abstract

Abnormal production or metabolism of steroid hormones is responsible for the development of endocrine diseases. Thus, accurate quantification of steroid hormones is needed for both research into clinical conditions and diagnostic and monitoring purposes. An improved analytical method for profiling 39 steroids in urine using LC-MS/MS was developed. As a pre-treatment procedure prior to LC-tandem mass spectrometry (LC-MS/MS) analysis, hydrolysis using β-glucuronidase and solid-phase extraction for purifying the samples were performed. Steroids were separated using Waters ACQUITY BEH C18 column (2.1 × 100 mm, 1.7 μm) and a mobile phase consisting of eluent A (0.01% formic acid and 1 mm ammonium formate in water) and eluent B (0.01% formic acid and 1 mm ammonium formate in methanol) with a gradient program at a flow rate of 0.4 mL/min. Under the optimized method, the linearity of calibration curves was higher than 0.992. The limits of detection at signal-to-noise ratio of 3 were 0.03-90 ng/mL. The developed novel LC-MS/MS method can quantitatively profile 39 steroids in a single analytical run. Steroid profiling based on quantitative results could improve the diagnosis and monitoring of hormone-dependent diseases.

Keywords: LC-MS/MS; metabolomics; quantitatively profile; steroid profiling.

PubMed Disclaimer

References

REFERENCES

    1. Barnard, G., & Kohen, F. (1998). Monitoring ovarian function by the simultaneous time-resolved fluorescence immunoassay of two urinary steroid metabolites. Clinical Chemistry, 44, 1520-1528.
    1. Caulfield, M. P., Lynn, T., Gottschalk, M. E., … Fisher, D. A. (2002). The diagnosis of congenital adrenal hyperplasia in the newborn by gas chromatography/mass spectrometry analysis of random urine specimens. The Journal of Clinical Endocrinology and Metabolism, 87, 3682-3690. https://doi.org/10.1210/jcem.87.8.8712
    1. Cho, S. H., Lee, S. K., & Kim, C. H. (2018). The determination of polycyclic aromatic hydrocarbons in human urine by high-resolution gas chromatography-mass spectrometry. Biomedical Chromatography: BMC, 32, e4166. https://doi.org/10.1002/bmc.4166
    1. Christakoudi, S., Cowan, D. A., & Taylor, N. F. (2010). Steroids excreted in urine by neonates with 21-hydroxylase deficiency: characterization, using GC-MS and GC-MS/MS, of the D-ring and side chain structure of pregnanes and pregnenes. Steroids, 75, 34-52. https://doi.org/10.1016/j.steroids.2009.09.011
    1. Falkenstein, E., Tillmann, H. C., Christ, M., Feuring, M., & Wehling, M. (2000). Multiple actions of steroid hormones--a focus on rapid, nongenomic effects. Pharmacological Reviews, 52, 513-556.

LinkOut - more resources