Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020;74(3):327-339.
doi: 10.3233/CH-190718.

Value of contrast-enhanced ultrasound (CEUS) in Focal Liver Lesions (FLL) with inconclusive findings on cross-sectional imaging

Affiliations

Value of contrast-enhanced ultrasound (CEUS) in Focal Liver Lesions (FLL) with inconclusive findings on cross-sectional imaging

Timo Alexander Auer et al. Clin Hemorheol Microcirc. 2020.

Abstract

Background: Contrast-enhanced ultrasound (CEUS) has been used as an additional imaging technique in order to evaluate focal liver lesions. CEUS is easy and fast to perform, overcomes the limitations of B-mode US.

Objective: To evaluate the diagnostic potential of contrast-enhanced ultrasound (CEUS) in focal liver lesions (FLL) with unclear findings on computed tomography (CT) or magnetic resonance imaging (MRI).

Methods: In this single-center retrospective study, 146 patients with at least one FLL underwent additional CEUS of the liver to clarify inconclusive cross-sectional imaging findings. Ultrasonography was performed using B-mode imaging and CEUS after injection of sulphur hexafluoride microbubbles (second-generation contrast agent) within two months after ceMRI or ceCT and interpreted by an experienced radiologist (EFSUMB level 3). Histopathological reports, long-term follow-up or clinical course served as reference standard.

Results: Thirty-eight of the 146 patients had malignant and 108 benign FLL. Overall, CEUS had 92% sensitivity (95% -CI, 79-97) and 98% specificity (95% -CI, 93-99) with an AUC of 0.95 in correctly characterizing the lesion as malignant or benign. Sensitivity increased to 98% (95% -CI, 96-100) for benign lesions and decreased to 92% (95% -CI, 78-98) for malignant lesions. CEUS showed the highest diagnostical accuracy in lesion <1 cm with an AUC of 1.000, while the lowest accuracy was achieved in lesions >2 cm with an AUC of 0.924 due to a decreasing specificity of 86% (95% -CI, 87-100).

Conclusion: CEUS correctly distinguished malignant from benign FLL in cases with inconclusive cross-sectional imaging findings and achieved high levels of diagnostic accuracy. CEUS has added diagnostic value especially in small lesions ≤1 cm while specificity remains limited in larger lesions.

Keywords: CEUS; contrast-enhanced ultrasound; focal liver lesions; liver ultrasound; sonography.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources