. 2020 Jun;109(6):755-760.
doi: 10.1007/s00392-019-01564-1. Epub 2019 Oct 31.

Outcome differences and device performance of the subcutaneous ICD in patients with and without structural heart disease

Affiliations

Outcome differences and device performance of the subcutaneous ICD in patients with and without structural heart disease

Kevin Willy et al. Clin Res Cardiol. 2020 Jun.

Abstract

Background: The performance of the subcutaneous ICD (S-ICD™) has been described in different kinds of heart disease and has been proven to be an important advance in prevention of sudden cardiac death (SCD). While positive experiences with the S-ICD™ initially came from collectives of patients without structural heart diseases, positive results have also been collected from cohorts with structural heart disease.

Materials and methods: All S-ICD™ patients with either ischemic cardiomyopathy (ICM), dilated cardiomyopathy (DCM) or hypertrophic cardiomyopathy (HCM) as the main indication for ICD implantation (n = 144 patients) or electrical heart disease/idiopathic ventricular fibrillation (n = 83 patients) in our large-scaled single-center S-ICD™ registry were included in this study. Baseline characteristics, appropriate and inappropriate shocks, and complications were documented in a mean follow-up of 18 ± 15 months.

Results: Baseline characteristics were significantly different between the two groups in most categories. In contrast, there was no difference concerning neither appropriate nor inappropriate shock delivery between the two groups. Also other outcome parameters such as need for surgical revisions and all-cause mortality did not differ. There was a significant difference between the first- and second-generation S-ICDs™ in inadequate shocks mainly driven by patients with HCM.

Conclusion: In our study, S-ICD™ performance was similar in patients with and without structural heart disease. Decision pro- or contra-S-ICD™ should be made rather on the basis of expected shock rate and probability of the need for future anti-tachycardia or anti-bradycardia pacing than in dependence of the underlying heart disease.

Keywords: Electrical heart disease; S-ICD; Structural heart disease; Sudden cardiac death.