A novel hybrid 3D endoscope zooming and repositioning system: Design and feasibility study

Affiliations

A novel hybrid 3D endoscope zooming and repositioning system: Design and feasibility study

Tim De Pauw et al. Int J Med Robot. 2020 Feb.

Abstract

Background: Manipulation of the endoscope during minimally invasive surgery is a major source of inconvenience and discomfort. This report elucidates the architecture of a novel one-hand controlled endoscope positioning device and presents a practicability evaluation.

Methods and materials: Setup time and total surgery time, number and duration of the manipulations, side effects of three-dimensional (3D) imaging, and ergonomic complaints were assessed by three surgeons during cadaveric and in vivo porcine trials.

Results: Setup was accomplished in an average (SD) of 230 (120) seconds. The manipulation time was 3.87 (1.77) seconds for angular movements and 0.83 (0.24) seconds for zooming, with an average (SD) of 30.5 (16.3) manipulations per procedure. No side effects of 3D imaging or ergonomic complaints were reported.

Conclusions: The integration of an active zoom into a passive endoscope holder delivers a convenient synergy between a human and a machine-controlled holding device. It is shown to be safe, simple, and intuitive to use and allows unrestrained autonomic control of the endoscope by the surgeon.

Keywords: endoscope positioner; minimally invasive surgery; solo surgery; surgical assistant.

PubMed Disclaimer

References

REFERENCES

    1. Mouret P. How I developed laparoscopic cholecystectomy. Ann Acad Med Singapore. 1996;25:744-747.
    1. Siddaiah-Subramanya M, Tiang KW, Nyandowe M. A new era of minimally invasive surgery: progress and development of major technical innovations in general surgery over the last decade. Surg J (N Y). 2017;3(4):e163-e166.
    1. Dewaele F, Kalmar AF, De Ryck F, et al. A novel design for steerable instruments based on laser-cut nitinol. Surg Innov. 2014;21(3):303-311.
    1. Yamashita H, Aoki H, Tanioka K, Mori T, et al. Ultra-high definition (8K UHD) endoscope: our first clinical success. Springerplus. 2016;5:1445. https://springerplus.springeropen.com/articles/10.1186/s40064-016-3135-z...
    1. Rigante M, La Rocca G, Lauretti L, et al. Preliminary experience with 4K ultra-high definition endoscope: analysis of pros and cons in skull base surgery. Acta Otorhinolaryngol Ital. 2017;37(3):237-241.

LinkOut - more resources