. 2019 Aug 19:13:1401-1414.
doi: 10.2147/PPA.S209717. eCollection 2019.

Inhaler technique errors in Romanian patients with asthma - a multicenter study

Affiliations

Inhaler technique errors in Romanian patients with asthma - a multicenter study

Laura Adela Munteanu et al. Patient Prefer Adherence. .

Abstract

Background: Non-adherence to treatment is associated with poor asthma control, increased exacerbations, decline in lung function, and decreased quality of life. M-health applications have become increasingly in the last years, but little research regarding the efficiency of the instructional videos for correct inhaler use exist. The aim of this study is to assess and improve the inhalator technique and to establish which types of errors were made more often with the help of a mobile health application.

Materials and methods: Seventy-five patients with partially controlled or uncontrolled asthma, using any of turbuhaler, diskus, pressurized metered dose inhaler (pMDI) or soft mist inhaler (SMI), were included in the study. When they first entered the study, the patient's inhaler technique was assessed by a trained medical professional and the technique errors were categorized in handling, respectively inhalation errors. After the first evaluation, the patients downloaded an application on their Smartphone and were encouraged to use the application as much as needed to remind them the correct inhalation technique. The patients were re-called every three months for evaluation, treatment, and assessment of inhalation technique.

Results: We analyzed both handling and inhalation errors for each of the four considered inhalers. We observed a significantly reduced number of inhalation technique errors after using the mobile phone application. Turbuhaler median errors were 6.00, and after six months we did not observe errors. Diskus median error was 6.00, and after six months we observed a maximum of one error. pMDI median errors were 7.00, and after six months we observed just one error. Similarly, SMI median error was 7.00, and after six months we observed just one error.

Conclusion: Although technique inhalation errors are very common among asthma patients, video instructions provided through specific mobile phone applications could improve the inhaler technique in order to achieve a better control of the disease.

Keywords: adherence; inhaler device; mobile phone application.

PubMed Disclaimer

Conflict of interest statement

The authors report no conflicts of interest in this work.

Figures

Figure 2
Figure 2
List of devices.
Figure 3
Figure 3
Device selection.
Figure 1
Figure 1
Application menu.
Figure 4
Figure 4
Instructional video.
Figure 5
Figure 5
Representation of both total errors (left) and critical errors (right) recorded by the Turbuhaler device at the three evaluation moments when patients were grouped by gender.
Figure 6
Figure 6
Representation of both total number of errors (left) and critical errors (right) recorded by the Diskus inhaler at the three evaluation moments when patients were grouped by gender.
Figure 7
Figure 7
Representation of the total number of errors (left) and the critical errors (right) recorded by the pMDI inhaler at the three evaluation moments when patients were grouped by gender.
Figure 8
Figure 8
Representation of both total number of errors (left) and critical errors (right) of the SMI inhaler at the three evaluation moments when patients were grouped by gender.
Figure 9
Figure 9
Representation of both total errors (left) and critical errors (right) recorded by the considered inhalers at the three evaluation moments.

References

    1. Bateman SS, Hurd PJ, Barnes J, et al. Zar European Respiratory Journal 2008;31:143–178. doi: 10.1183/09031936.00138707 - DOI - PubMed
    1. Demoly P, Paggiaro P, Plaza V, Bolge SC, Kannan H, Sohier B. Prevalence of asthma control among adults in France, Germany, Italy, Spain and the UK. Eur Respir Rev. 2009;112(18):105–112. doi: 10.1183/09059180.00001209 - DOI - PubMed
    1. Miller L, Schüz B, Walters J, Walters EH. Mobile technology interventions for asthma self-management: systematic review and meta-analysis. JMIR mHealth uHealth. 2017;5(5):e57. doi: 10.2196/mhealth.7168 - DOI - PMC - PubMed
    1. Rascu A, Elena Popa D, Arghir O, Otelea M. Effects of corticosteroid treatment on respiratory muscles function in patients with severe obstructive lung disease. Farmacia 2016;64(6):819–822.
    1. Levy ML. The national review of asthma deaths: what did we learn and what needs to change? Breathe. 2015;11(1):15–24. doi: 10.1183/20734735.008914 - DOI - PMC - PubMed

LinkOut - more resources