. 2020 Dec;30(4):749-759.
doi: 10.1007/s00062-019-00844-7. Epub 2019 Nov 6.

Systematic Evaluation of Low-dose MDCT for Planning Purposes of Lumbosacral Periradicular Infiltrations

Affiliations

Systematic Evaluation of Low-dose MDCT for Planning Purposes of Lumbosacral Periradicular Infiltrations

Nico Sollmann et al. Clin Neuroradiol. 2020 Dec.

Abstract

Purpose: To evaluate image quality and confidence for planning of periradicular infiltrations using virtually lowered tube currents and in-house developed iterative reconstruction (IR) for multidetector computed tomography (MDCT).

Methods: A total of 20 patients (mean age 54.9 ± 13.1 years) underwent MDCT for planning purposes of periradicular infiltrations at the lumbosacral spine (120 kVp and 100 mAs). Planning scans were simulated as if they were performed at 50% (D50), 10% (D10), 5% (D5), and 1% (D1) of the tube current of original scanning. Image reconstruction was achieved with two levels of IR (A: similar in appearance to clinical reconstructions, B: 10 times stronger noise reduction). Qualitative image evaluation was performed by two readers (R1 and R2) considering overall image quality and artifacts, image contrast, determination of nerve root, and confidence for intervention planning (scoring: 1 high, 2 medium, and 3 low confidence).

Results: Level A of IR was favorable regarding overall image quality, artifacts, image contrast, and nerve root depiction according to both readers, with preserved good to excellent scores down to D10 scans. The confidence for intervention planning was not significantly different (p > 0.05) between scans with tube currents virtually lowered down to 10% as compared to the original scans when using level A of IR (R1: 1.2 ± 0.4, R2: 1.1 ± 0.3). Inter-reader agreement for planning confidence was good to excellent (range of weighted Cohen's kappa: 0.62-1.00).

Conclusion: The use of MDCT for planning purposes of lumbosacral periradicular infiltrations may be possible with tube currents lowered down to 10% of standard dose (equal to 10 mAs) without limitations in planning confidence.

Keywords: Image processing; Interventional radiology; Multidetector computed tomography; Radiation dosage; Spine.

PubMed Disclaimer

References

    1. Karppinen J, Malmivaara A, Kurunlahti M, Kyllönen E, Pienimäki T, Nieminen P, Ohinmaa A, Tervonen O, Vanharanta H.. Periradicular infiltration for sciatica: a randomized controlled trial. Spine (Phila Pa 1976). 2001;26:1059–67. - DOI
    1. Andreula C, Muto M, Leonardi M. Interventional spinal procedures. Eur J Radiol. 2004;50:112–9. - DOI
    1. Palmer WE. Spinal injections for pain management. Radiology. 2016;281:669–88. - DOI
    1. Waggershauser T, Schwarzkopf S, Reiser M. Facet blockade, peridural and periradicular pain therapy. Radiologe. 2006;46:520–6. - DOI
    1. Seibel RM. Image-guided minimally invasive therapy. Surg Endosc. 1997;11:154–62. - DOI

LinkOut - more resources