Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2019 Nov 6:14:47.
doi: 10.1186/s13006-019-0237-6. eCollection 2019.

Comparison of maternal milk ejection characteristics during pumping using infant-derived and 2-phase vacuum patterns

Affiliations
Randomized Controlled Trial

Comparison of maternal milk ejection characteristics during pumping using infant-derived and 2-phase vacuum patterns

Hazel Gardner et al. Int Breastfeed J. .

Abstract

Background: Milk ejection characteristics remain consistent throughout 12 months of lactation in women who expressed breastmilk with an electric breast pump. In addition these characteristics appear to remain constant when women are breastfeeding or pumping suggesting that milk ejection is a robust physiological response. It is not known whether the stimulation of an infant at the breast in the early post partum period influences milk ejection patterns or whether this is a programmed event. However, as more data become available on the mechanisms involved in infant feeding, pumping patterns mimicking the infant more closely may provide enhanced results. The objective of this study was to compare milk ejection characteristics obtained when using a novel infant-derived pumping pattern with an established 2-phase pattern.

Methods: A convenience sample of ten lactating mothers, 1 to 40 weeks of lactation with normal milk production were recruited in 2015. Each participated in two pumping sessions in which either a 2-phase pattern or infant-derived pattern were randomly assigned. Milk volume and milk ejection characteristics were recorded and the percentage of available milk removed (PAMR) was calculated. Statistical analysis used linear mixed effects modeling to determine any differences between breasts and pump patterns with the consideration of individual variability as a random effect.

Results: The number of milk ejections and milk ejection characteristics did not differ between patterns. Milk volumes removed were 53.6 ± 28.5 ml (PAMR 58.2 ± 28.4) for the 2-phase pattern and and 54.2 ± 26.3 ml (PAMR 52.2 ± 22.3) for the infant derived pattern. Peak milk flow rates were positively associated with the available milk (p = 0.0003) and PAMR (p = 0.0001), as was the volume of milk removed during each milk ejection (p = 0.001 and p = 0.0001).

Conclusion: An experimental pumping pattern designed to resemble infant sucking characteristics did not alter milk ejection characteristics or milk removal parameters compared with an established 2-phase pattern. Theses findings provide further evidence that milk ejection is a robust physiological response.

Keywords: Breastmilk; Infant feeding; Lactation; Milk expression.

PubMed Disclaimer

Conflict of interest statement

Competing interestsHG, JK, CTL & DG are supported by an unrestricted research grant from Medela AG. Baar, Switzerland.

Figures

Fig. 1
Fig. 1
Research protocol to examine differences in milk ejection characteristics using Symphony and infant-derived pump patterns
Fig. 2
Fig. 2
Vacuum curves for the 2-phase and infant-derived pump patterns
Fig. 3
Fig. 3
Duration of milk ejections (ME) for right and left breasts using 2-phase and infant patterns
Fig. 4
Fig. 4
Time to peak flow rate during milk ejections using 2-phase and infant-derived patterns

References

    1. Wilde CJ, Addey CV, Boddy LM, Peaker M. Autocrine regulation of milk secretion by a protein in milk. Biochem J. 1995;305(1):51–58. doi: 10.1042/bj3050051. - DOI - PMC - PubMed
    1. Linzell J, Peaker M. Mechanism of milk secretion. Physiol Rev. 1971;51(3):564–597. doi: 10.1152/physrev.1971.51.3.564. - DOI - PubMed
    1. Ramsay DT, Kent JC, Owens RA, Hartmann PE. Ultrasound imaging of milk ejection in the breast of lactating women. Pediatrics. 2004;113(2):361–367. doi: 10.1542/peds.113.2.361. - DOI - PubMed
    1. Richardson KC. Contractile tissues in the mammary gland, with special reference to myoepithelium in the goat. Proc R Soc Lond B Biol Sci. 1949;136(882):30–45. doi: 10.1098/rspb.1949.0004. - DOI - PubMed
    1. Kent JC. How breastfeeding works. J Midwifery Womens Health. 2007;52(6):564–570. doi: 10.1016/j.jmwh.2007.04.007. - DOI - PubMed

Publication types