Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2020 Mar;157(3):702-711.
doi: 10.1016/j.chest.2019.10.025. Epub 2019 Nov 9.

The Impact of Gravity vs Suction-driven Therapeutic Thoracentesis on Pressure-related Complications: The GRAVITAS Multicenter Randomized Controlled Trial

Affiliations
Randomized Controlled Trial

The Impact of Gravity vs Suction-driven Therapeutic Thoracentesis on Pressure-related Complications: The GRAVITAS Multicenter Randomized Controlled Trial

Robert J Lentz et al. Chest. 2020 Mar.

Abstract

Background: Thoracentesis can be accomplished by active aspiration or drainage with gravity. This trial investigated whether gravity drainage could protect against negative pressure-related complications such as chest discomfort, re-expansion pulmonary edema, or pneumothorax compared with active aspiration.

Methods: This prospective, multicenter, single-blind, randomized controlled trial allocated patients with large free-flowing effusions estimated ≥ 500 mL 1:1 to undergo active aspiration or gravity drainage. Patients rated chest discomfort on 100-mm visual analog scales prior to, during, and following drainage. Thoracentesis was halted at complete evacuation or for persistent chest discomfort, intractable cough, or other complication. The primary outcome was overall procedural chest discomfort scored 5 min following the procedure. Secondary outcomes included measures of discomfort and breathlessness through 48 h postprocedure.

Results: A total of 142 patients were randomized to undergo treatment, with 140 in the final analysis. Groups did not differ for the primary outcome (mean visual analog scale score difference, 5.3 mm; 95% CI, -2.4 to 13.0; P = .17). Secondary outcomes of discomfort and dyspnea did not differ between groups. Comparable volumes were drained in both groups, but the procedure duration was significantly longer in the gravity arm (mean difference, 7.4 min; 95% CI, 10.2 to 4.6; P < .001). There were no serious complications.

Conclusions: Thoracentesis via active aspiration and gravity drainage are both safe and result in comparable levels of procedural comfort and dyspnea improvement. Active aspiration requires less total procedural time.

Trial registry: ClinicalTrials.gov; No.: NCT03591952; URL: www.clinicaltrials.gov.

Keywords: gravity; pleural effusion; suction; thoracentesis.

PubMed Disclaimer

Comment in

Publication types

Associated data