[Comparison of clinical and functional results of conventional and femtosecond laser-assisted cataract phacoemulsification]

[Article in Russian]
Affiliations

[Comparison of clinical and functional results of conventional and femtosecond laser-assisted cataract phacoemulsification]

[Article in Russian]
B E Malugin et al. Vestn Oftalmol. 2019.

Abstract

Purpose: To perform a comparative analysis of ultrasound and hydrodynamic parameters, and the outcomes of femtosecond laser-assisted cataract surgery (FLACS) and conventional phacoemulsification cataract surgery (CPCS).

Material and methods: This prospective cohort study included 246 eyes. The first group consisted of 138 patients who underwent FLACS, second group - 108 patients after CPCS.

Results: Total ultrasound time was 95.36±47.93 and 113.3±97.71 seconds (p=0.04) in the 1st and the 2nd groups, respectively. The duration of torsional ultrasound was 84.72±50.03 seconds in 1st group (p=0.04) and 113.3±97.71 seconds in the 2nd group (p=0.04). Aspiration time was 208.3±95.86 seconds in the 1st group (p=0.04) and 258.43±158.81 seconds in the 2nd group (p=0.04). On the 3-4th day after the surgery, uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) were significantly better in the 1st group - 0.62±0.21 (LogMAR 0.20±0.19) and 0.53±0.15 (LogMAR 0.30±0.21) (p=0.01), respectively, compared to the 2nd group with UDVA of 0.75±0.18 (LogMAR 0.10±0.16) and CDVA of 0.69±0.19 (LogMAR 0.20±0.15) (p=0.04). Central corneal thickness (CCT) was 573.41±33.12 and 632.43±58.30 μm in the 1st and 2nd groups, respectively (p=0.020). At 1 month post-op there were no statistically significant differences in UDVA (p=0.17), CDVA (p=0.40) or CCT (p=0.50) between the groups.

Conclusion: Compared with CPCS, total ultrasound time (p=0.04), torsional ultrasound time (p=0.04) and aspiration time (p=0.04) were significantly lower in the FLACS group. CCT was significantly lower (p=0.02), while UDVA (p=0.04) and CDVA (p=0.01) were significantly higher in the FLACS group in the early post-operative period (3-4 days after surgery). There were no statistically significant differences in the parameters between the groups 1 month after the surgery.

Цель исследования - провести сравнительный анализ интраоперационных энергетических и гидродинамических параметров, а также клинико-функциональных результатов после фемтолазерассистированной экстракции катаракты (ФЛАЭК) и традиционной факоэмульсификации катаракты (ФЭК). Материал и методы. В данном проспективном исследовании участвовали 246 пациентов: 1-ю группу (основную) составили 138 человек, которым выполнена ФЛАЭК, 2-ю группу (сравнения) - 108 пациентов, которым проведена традиционная ФЭК. Результаты. Общее время ультразвука в 1-й группе составило 95,36±47,93 с во 2-й - 125,12±101,94 с (р=0,04), торсионного ультразвука - 84,72±50,03 и 113,3±97,71 с соответственно (р=0,04), время действия аспирации - 208,3±95,86 и 258,43±158,81 с соответственно (р=0,04). При выписке средние показатели некорригированной (НКОЗ) и корригированной (КОЗ) остроты зрения статистически значимо были выше в 1-й группе по сравнению с аналогичными показателями во 2-й группе и составили в среднем 0,62±0,21 (LogMAR 0,20±0,19) и 0,53±0,15 (LogMAR 0,30±0,21) (р=0,01), 0,75±0,18 (LogMAR 0,10±0,16) и 0,69±0,19 (LogMAR 0,20±0,15) (р=0,04) соответственно. Толщина роговицы в центре составила 573,41±33,12 и 632,43±58,30 мкм в 1-й и 2-й группах соответственно (p=0,020). Через 1 мес НКОЗ (р=0,17), КОЗ (р=0,40) и толщина роговицы (р=0,50) в обеих группах статистически значимо не отличались. Заключение. ФЛАЭК обеспечивает статистически значимое сокращение общего времени работы продольного (р=0,04) и торсионного (р=0,04) ультразвука, а также аспирации (р=0,04) на этапе эвакуации хрусталика по сравнению с аналогичными показателями при традиционной ФЭК. В раннем послеоперационном периоде статистически значимо центральная толщина роговицы была меньше (р=0,02), а показатели КОЗ (р=0,01) и НКОЗ (р=0,04) выше в группе ФЛАЭК. Через 1 мес после операции все исследуемые показатели в обеих группах статистически значимо не отличались.

Keywords: CPCS; FLACS; cataract; femtosecond laser-assisted cataract surgery.