Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2020 Apr:64:54-61.
doi: 10.1016/j.avsg.2019.11.013. Epub 2019 Nov 11.

Peroperative Intravascular Ultrasound for Endovascular Aneurysm Repair versus Peroperative Angiography: A Pilot Study in Fit Patients with Favorable Anatomy

Affiliations
Comparative Study

Peroperative Intravascular Ultrasound for Endovascular Aneurysm Repair versus Peroperative Angiography: A Pilot Study in Fit Patients with Favorable Anatomy

Giulio Illuminati et al. Ann Vasc Surg. 2020 Apr.

Abstract

Background: The aim of this study was to compare intravascular ultrasound (IVUS) assistance for endovascular aortic aneurysm repair (EVAR) to standard assistance by angiography.

Methods: From June 2015 to June 2017, 173 consecutive patients underwent EVAR. In this group, 69 procedures were IVUS-assisted with X-ray exposure limited to completion angiography for safety purposes because an IVUS probe does not yet incorporate a duplex probe (group A), and 104 were angiography-assisted procedures (group B). All IVUS-assisted procedures were performed by vascular surgeons with basic duplex ultrasound (DUS) training. The primary study endpoints were mean radiation dose, duration of fluoroscopy, amount of contrast media administered, procedure-related outcomes, and renal clearance expressed as the glomerular filtration rate (GFR) before and after the procedure. Secondary endpoints were operative mortality, morbidity, and arterial access complications.

Results: Mean duration of fluoroscopy time was significantly lower for IVUS-assisted procedures (24 ± 15 min vs. 40 ± 30 min for angiography-assisted procedures, P < 0.01). Moreover, mean radiation dose (Air KERMA) was significantly lower in IVUS-assisted procedures (76m Gy [44-102] vs. 131 mGy [58-494]), P < 0.01. IVUS-assisted procedures required fewer contrast media than standard angiography-assisted procedures (60 ± 20 mL vs. 120 ± 40 mL, P < 0.01). The mean duration of the procedure was comparable in the two groups (120 ± 30 min vs. 140 ± 30 min, P = 0.07). No difference in renal clearance before and after the procedure was observed in either of the two groups (99.0 ± 4/97.8 ± 2 mL/min in group A and 98.0 ± 3/97.6 ± 5 mL/min in group B) (P = 0.28). The mean length of follow-up was nine months (6-30 months). No postoperative mortality, morbidity, or arterial access complications occurred. No type 1 endoleak was observed. Early type II endoleaks were observed in 21 patients (11%), 12 in the angiography-assisted group (11%) and nine in the IVUS-assisted group (12%). They were not associated with sac enlargement ≥5 mm diameter and therefore did not require any additional treatment.

Conclusions: Compared with standard angiography-assisted EVAR, IVUS significantly reduces renal load with contrast media, fluoroscopy time, and radiation dose while preserving endograft deployment efficiency. Confirmation from a large prospective study with improved IVUS probes will be required before IVUS-assisted EVAR alone can become standard practice.

PubMed Disclaimer

Comment in

Publication types

MeSH terms

LinkOut - more resources