Relationship between shear modulus and passive tension of the posterior shoulder capsule using ultrasound shear wave elastography: A cadaveric study
- PMID: 31735360
- DOI: 10.1016/j.jbiomech.2019.109498
Relationship between shear modulus and passive tension of the posterior shoulder capsule using ultrasound shear wave elastography: A cadaveric study
Abstract
Although shear wave elastography (SWE) has been used to indirectly measure passive tension in muscle tissues, it is unknown whether SWE can adequately evaluate passive tension in capsule tissues. This study investigated the relationship between the shear modulus and passive tension in the posterior shoulder capsule using SWE. Ten posterior middle and ten posterior inferior shoulder capsules were dissected from ten fresh-frozen cadavers; humeral head-capsule-glenoid specimens were created from each capsule. The humeral head and glenoid were immobilized with clamps in a custom-built device. Loads (0-400 g, in 25-g increments) were applied to each capsule via a pulley system; elasticity was simultaneously measured using SWE. The elasticity-load relationship of each tested capsule was analyzed by fitting a least-squares regression line to the data. Elasticity change due to creep or hysteresis effects was evaluated by comparing the elastic modulus for a 100-g load during and after the stepwise application of the loads. The observed relationship between the shear modulus and passive capsule tension was highly linear for all twenty tested capsules (p < 0.01). The mean coefficient of determination was 0.882 ± 0.075 and 0.901 ± 0.050 for the posterior middle and posterior inferior capsules, respectively. There was no difference in the shear modulus between the two 100-g load assessments for both the posterior middle (p = 0.205) and posterior inferior capsules (p = 0.161). Thus, SWE is a valid and useful method for indirectly evaluating the change in the passive tension under loading in specific posterior shoulder capsule.
Keywords: Elasticity; Posterior shoulder tightness; Stiffness; Stretching.
Copyright © 2019 Elsevier Ltd. All rights reserved.
Similar articles
-
Effective stretching positions for the posterior shoulder capsule as determined by shear wave elastography.J Shoulder Elbow Surg. 2021 May;30(5):1186-1195. doi: 10.1016/j.jse.2020.08.021. Epub 2020 Sep 9. J Shoulder Elbow Surg. 2021. PMID: 32919046
-
Posterior Shoulder Capsules Are Thicker and Stiffer in the Throwing Shoulders of Healthy College Baseball Players: A Quantitative Assessment Using Shear-Wave Ultrasound Elastography.Am J Sports Med. 2015 Dec;43(12):2935-42. doi: 10.1177/0363546515608476. Epub 2015 Oct 15. Am J Sports Med. 2015. PMID: 26473012
-
Can Shoulder Muscle Activity Be Evaluated With Ultrasound Shear Wave Elastography?Clin Orthop Relat Res. 2018 Jun;476(6):1276-1283. doi: 10.1097/01.blo.0000533628.06091.0a. Clin Orthop Relat Res. 2018. PMID: 29698293 Free PMC article.
-
Relationship between shear elastic modulus and passive force of the human rectus femoris at multiple sites: a Thiel soft-embalmed cadaver study.J Med Ultrason (2001). 2021 Apr;48(2):115-121. doi: 10.1007/s10396-020-01076-w. Epub 2021 Feb 12. J Med Ultrason (2001). 2021. PMID: 33576917
-
A review of physical and engineering factors potentially affecting shear wave elastography.J Med Ultrason (2001). 2021 Oct;48(4):403-414. doi: 10.1007/s10396-021-01127-w. Epub 2021 Aug 28. J Med Ultrason (2001). 2021. PMID: 34453649 Free PMC article. Review.
Cited by
-
Relationship between shear elastic modulus and passive muscle force in human hamstring muscles using a Thiel soft-embalmed cadaver.J Med Ultrason (2001). 2023 Jul;50(3):275-283. doi: 10.1007/s10396-023-01317-8. Epub 2023 May 11. J Med Ultrason (2001). 2023. PMID: 37170041 Free PMC article.
-
Are Rotator Muscle Performance and Posterior Shoulder Capsule Tightness Related to Glenohumeral Internal Rotation Deficit in Male College Baseball Players?Clin Orthop Surg. 2022 Dec;14(4):576-584. doi: 10.4055/cios21212. Epub 2022 Aug 16. Clin Orthop Surg. 2022. PMID: 36518941 Free PMC article.
-
The combined importance of finite dimensions, anisotropy, and pre-stress in acoustoelastography.J Acoust Soc Am. 2022 Apr;151(4):2403. doi: 10.1121/10.0010110. J Acoust Soc Am. 2022. PMID: 35461517 Free PMC article. Review.
-
Shear wave elastography ultrasound does not quantify mechanical properties of the ulnar collateral ligament of the elbow.J Ultrasound. 2024 Sep;27(3):441-447. doi: 10.1007/s40477-022-00768-y. Epub 2023 Feb 15. J Ultrasound. 2024. PMID: 36790657 Free PMC article.
-
Changes of Material Elastic Properties during Healing of Ruptured Achilles Tendons Measured with Shear Wave Elastography: A Pilot Study.Int J Mol Sci. 2020 May 12;21(10):3427. doi: 10.3390/ijms21103427. Int J Mol Sci. 2020. PMID: 32408704 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical