Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Feb 15;95(3):471-476.
doi: 10.1002/ccd.28598. Epub 2019 Nov 19.

Percutaneous intraluminal downsizing of systemic-to-pulmonary artery shunts: a novel application of the Diabolo stent technique-Case series and description of the technique

Affiliations

Percutaneous intraluminal downsizing of systemic-to-pulmonary artery shunts: a novel application of the Diabolo stent technique-Case series and description of the technique

Nicola Maschietto et al. Catheter Cardiovasc Interv. .

Abstract

Objective: This article aims to describe the feasibility of a novel application of the Diabolo stent technique for percutaneous downsizing of systemic-to-pulmonary artery shunts in patients with pulmonary overcirculation.

Background: Pulmonary overcirculation can lead to systemic hypoperfusion, impaired systemic oxygen delivery, and hemodynamic instability especially in patients with single-ventricle physiology. Different medical and surgical strategies to treat pulmonary overcirculation have been reported so far, but no percutaneous approach amenable to further adjustment over time has been described.

Methods: Retrospective review of patients who underwent percutaneous intraluminal reduction of a systemic-to-pulmonary artery shunt with a covered stent in a Diabolo "hour-glass" configuration.

Results: From July 2018 to February 4, 2019, consecutive patients underwent trans-catheter downsizing of a systemic-to-pulmonary artery shunt. The median age was 3.3 years (range 0.7-5.7 years). All patients had symptomatic pulmonary overflow despite maximal medical therapy. All patients underwent successful implantation of a covered stent in a Diabolo "hour-glass" configuration without any complications. Successful reduction in pulmonary overcirculation was noted in all patients with a decrease of mean pulmonary artery pressure from a median of 29 mmHg (range 25-32 mmHg) to a median of 21 mmHg (range 14-27 mmHg).

Conclusions: Percutaneous intraluminal downsizing of systemic-to-pulmonary artery shunts with a covered stent in a Diabolo configuration is safe and feasible. With this technique, the pulmonary blood flow can be adjusted in a physiologic closed-chest condition and further regulated over time.

Keywords: Diabolo stent; congenital heart disease; covered stent; pulmonary overcirculation.

PubMed Disclaimer

References

REFERENCES

    1. Tabbutt S, Tweddell JS, Ghanayem N. Hypoplastic left heart syndrome and other shunt-dependent single ventricles. Pediatr Crit Care Med. 2016;17(8):S318-S322.
    1. Lowry AW. Resuscitation and perioperative management of the high-risk single ventricle patient: first-stage palliation. Congenit Heart Dis. 2012;7(5):466-478.
    1. Dirks V, Prêtre R, Knirsch W, et al. Modified Blalock Taussig shunt: a not-so-simple palliative procedure. Eur J Cardio-Thoracic Surg. 2013;44(6):1096-1102.
    1. Graham EM, Forbus GA, Bradley SM, Shirali GS, Atz AM. Incidence and outcome of cardiopulmonary resuscitation in patients with shunted single ventricle: advantage of right ventricle to pulmonary artery shunt. J Thorac Cardiovasc Surg. 2006;131(5):7-8.
    1. Stumper O, Gewillig M, Vettukattil J, et al. Modified technique of stent fenestration of the atrial septum. Heart. 2003;89:1227-1230.

Publication types

MeSH terms

LinkOut - more resources