Percutaneous intraluminal downsizing of systemic-to-pulmonary artery shunts: a novel application of the Diabolo stent technique-Case series and description of the technique
- PMID: 31743550
- DOI: 10.1002/ccd.28598
Percutaneous intraluminal downsizing of systemic-to-pulmonary artery shunts: a novel application of the Diabolo stent technique-Case series and description of the technique
Abstract
Objective: This article aims to describe the feasibility of a novel application of the Diabolo stent technique for percutaneous downsizing of systemic-to-pulmonary artery shunts in patients with pulmonary overcirculation.
Background: Pulmonary overcirculation can lead to systemic hypoperfusion, impaired systemic oxygen delivery, and hemodynamic instability especially in patients with single-ventricle physiology. Different medical and surgical strategies to treat pulmonary overcirculation have been reported so far, but no percutaneous approach amenable to further adjustment over time has been described.
Methods: Retrospective review of patients who underwent percutaneous intraluminal reduction of a systemic-to-pulmonary artery shunt with a covered stent in a Diabolo "hour-glass" configuration.
Results: From July 2018 to February 4, 2019, consecutive patients underwent trans-catheter downsizing of a systemic-to-pulmonary artery shunt. The median age was 3.3 years (range 0.7-5.7 years). All patients had symptomatic pulmonary overflow despite maximal medical therapy. All patients underwent successful implantation of a covered stent in a Diabolo "hour-glass" configuration without any complications. Successful reduction in pulmonary overcirculation was noted in all patients with a decrease of mean pulmonary artery pressure from a median of 29 mmHg (range 25-32 mmHg) to a median of 21 mmHg (range 14-27 mmHg).
Conclusions: Percutaneous intraluminal downsizing of systemic-to-pulmonary artery shunts with a covered stent in a Diabolo configuration is safe and feasible. With this technique, the pulmonary blood flow can be adjusted in a physiologic closed-chest condition and further regulated over time.
Keywords: Diabolo stent; congenital heart disease; covered stent; pulmonary overcirculation.
© 2019 Wiley Periodicals, Inc.
References
REFERENCES
-
- Tabbutt S, Tweddell JS, Ghanayem N. Hypoplastic left heart syndrome and other shunt-dependent single ventricles. Pediatr Crit Care Med. 2016;17(8):S318-S322.
-
- Lowry AW. Resuscitation and perioperative management of the high-risk single ventricle patient: first-stage palliation. Congenit Heart Dis. 2012;7(5):466-478.
-
- Dirks V, Prêtre R, Knirsch W, et al. Modified Blalock Taussig shunt: a not-so-simple palliative procedure. Eur J Cardio-Thoracic Surg. 2013;44(6):1096-1102.
-
- Graham EM, Forbus GA, Bradley SM, Shirali GS, Atz AM. Incidence and outcome of cardiopulmonary resuscitation in patients with shunted single ventricle: advantage of right ventricle to pulmonary artery shunt. J Thorac Cardiovasc Surg. 2006;131(5):7-8.
-
- Stumper O, Gewillig M, Vettukattil J, et al. Modified technique of stent fenestration of the atrial septum. Heart. 2003;89:1227-1230.