Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 May;27(4):251-261.
doi: 10.1080/10749357.2019.1691815. Epub 2019 Nov 21.

Validation of stroke-specific protocols for the 10-meter walk test and 6-minute walk test conducted using 15-meter and 30-meter walkways

Affiliations

Validation of stroke-specific protocols for the 10-meter walk test and 6-minute walk test conducted using 15-meter and 30-meter walkways

Darren K Cheng et al. Top Stroke Rehabil. 2020 May.

Abstract

Background: Stroke-specific protocols for the 10-meter and 6-minute walk tests that include instructions for people with aphasia, accessible walkway lengths, and allow provision of assistance to walk are needed to facilitate uptake in hospital settings.Objectives: To estimate the test-retest reliability, measurement error, and construct validity of stroke-specific protocols for the 10-meter walk test (10mWT), and 6-minute walk test conducted using a 15-meter walkway (6MWT15m) and 30-meter walkway (6MWT30m), in people post-stroke.Methods: A quantitative, cross-sectional study involving ambulatory people post-stroke was conducted.Results: Data were collected from 21 and 20 participants at baseline and retest, respectively, 1-3 days apart. Mean age was 61 years, median time post-stroke was 134 days, and 90% had experienced an ischemic stroke. Performance on the 10mWT, 6MWT15m, and 6MWT30m across sessions yielded intraclass correlation coefficient (ICC2, 1) estimates of test-retest reliability of 0.83, 0.97, 0.95, respectively, and minimal detectable change values at the 95% confidence level of 0.40m/s, 44.0m, and 67.5m, respectively. Pearson correlation coefficients were 0.80-0.95 (p < .001) between results on all three walk tests and 0.27-0.48 (p < .25) between walk test results and strength subscale scores on the Stroke Impact Scale.Conclusions: Findings showed excellent test-retest reliability; measurement error values similar to current literature; and support for construct validity of the 10mWT, 6MWT15m, and 6MWT30m. Due to the shorter walkway, the 6MWT15m may be more feasible to implement than the 6MWT30m in hospital settings. A larger sample with more severe deficits is required to improve generalizability.

Keywords: Stroke; gait speed; measurement error; reliability; validity; walk test; walking capacity.

PubMed Disclaimer

Similar articles

Cited by

Publication types