Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Mar-Apr;10(2):84-92.
doi: 10.1016/j.prro.2019.11.012. Epub 2019 Nov 29.

Quantification of Esophageal Tumor Motion and Investigation of Different Image-Guided Correction Strategies

Affiliations

Quantification of Esophageal Tumor Motion and Investigation of Different Image-Guided Correction Strategies

Francine E M Voncken et al. Pract Radiat Oncol. 2020 Mar-Apr.

Abstract

Purpose: To accurately quantify esophageal tumor position variability and to optimize image guided correction strategies.

Material and methods: Esophageal cancer patients receiving chemoradiotherapy (41.4-50.4 Gy in 23-28 fractions combined with carboplatin plus paclitaxel) were included in a prospective cohort study (NCT02139488). Gold fiducial markers were inserted into the esophageal tumors during diagnostic endoscopic ultrasound. Four-dimensional (4D) planning computed tomography (CT) and daily 4D cone beam (CB) CT scans were acquired. Each CBCT was registered to the planning CT using different regions of interest (bone; 3D), and carina, diaphragm, clinical target volume (CTV), and fiducial markers (4D) for alignment and using the fiducial markers as the true tumor position. Subsequently, a planning target volume (PTV) margin accounting for residual uncertainties, including the average respiratory motion, was calculated for each of these registrations.

Results: Fifty-six patients with tumors located in the proximal (n = 1), mid (n = 7), or distal esophagus (n = 25) or at the gastroesophageal junction (n = 23) were included. The average peak-to-peak respiratory tumor motion was 0.20, 0.92, and 0.34 cm on the planning CT in left-right (LR), cranial-caudal (CC), and anterior-posterior (AP) directions, respectively. The required PTV margin with average motion amplitude, depending on the correction strategy used for image guidance, ranged from 0.8 cm to 1.0 cm, 1.1 cm to 1.6 cm, and 0.7 cm to 0.9 cm in LR, CC, and AP direction, respectively. A registration based on the CTV resulted in the smallest PTV margins (0.8, 1.1, and 0.7 cm in LR, CC, and AP direction, respectively). For bone registration the calculated PTV margins were 1.0, 1.3, and 0.7 cm in LR, CC, and AP directions, respectively. The registration based on the diaphragm increased PTV margins.

Conclusions: Substantial and anisotropic position variability of esophageal tumors was observed during radiation therapy, and nonuniform margins should be considered. Cranial-caudal PTV margins need to be larger than those commonly used. Target positioning during image-guided radiotherapy could be improved with a CTV registration-based correction strategy.

PubMed Disclaimer

LinkOut - more resources