. 2020 Jan;36(1):225-232.
doi: 10.1016/j.arthro.2019.07.023. Epub 2019 Nov 29.

All-Inside Lateral Meniscal Repair via Anterolateral Portal Increases Risk of Vascular Injury: A Cadaveric Study

Affiliations

All-Inside Lateral Meniscal Repair via Anterolateral Portal Increases Risk of Vascular Injury: A Cadaveric Study

David Weijia Mao et al. Arthroscopy. 2020 Jan.

Abstract

Purpose: To compare the distance from the device tip to the neurovascular structures during an all-inside medial and lateral meniscal repair using anteromedial and anterolateral portals in a fresh-frozen cadaveric study.

Methods: Ten fresh-frozen cadaveric knees were studied. The popliteal artery, popliteal vein, and tibial nerve were identified after dissection via a posterior approach. An all-inside meniscal repair device was set to a 20-mm depth limit and inserted into a fixed point in the posterior horn at the meniscocapsular junction. This was performed for medial and lateral menisci via anteromedial and anterolateral arthroscopic portals. The distances between the device tip and the neurovascular structures were measured. We performed t tests to determine statistical significance.

Results: The distance between the device and popliteal artery was significantly closer when aimed at the posterior horn of the lateral meniscus via the anterolateral portal (4.7 ± 2.3 mm) versus the anteromedial portal (13.0 ± 8.0 mm, P = .010). The distance to the popliteal vein was closer via the anterolateral portal (6.7 ± 2.9 mm) versus the anteromedial portal (13.9 ± 5.8 mm, P = .004). For medial meniscal repair, the distance to the popliteal artery was significantly closer via the anteromedial portal (12.8 ± 11.3 mm) versus the anterolateral portal (23.8 ± 7.7 mm, P = .022). The distance to the popliteal vein was closer via the anteromedial portal (16.5 ± 11.3 mm) versus the anterolateral portal (28.3 ± 8.2 mm, P = .017). No significant difference was found in the distance to the tibial nerve when aimed at either meniscus via either portal.

Conclusion: For all-inside meniscal repair, the popliteal vein is at risk and the popliteal artery is at high risk of injury when the posterior horn of the lateral meniscus is repaired via an anterolateral working portal.

Clinical relevance: The popliteal artery and vein are at risk of injury when the posterior horn of the lateral meniscus undergoes all-inside repair via the anterolateral portal. Surgeons need to be aware of the risks when performing this repair.

PubMed Disclaimer

LinkOut - more resources