Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2020 Jan:306:110063.
doi: 10.1016/j.forsciint.2019.110063. Epub 2019 Nov 15.

New strategy for carbon monoxide poisoning diagnosis: Carboxyhemoglobin (COHb) vs Total Blood Carbon Monoxide (TBCO)

Affiliations
Comparative Study

New strategy for carbon monoxide poisoning diagnosis: Carboxyhemoglobin (COHb) vs Total Blood Carbon Monoxide (TBCO)

Stefania Oliverio et al. Forensic Sci Int. 2020 Jan.

Abstract

Diagnosis of carbon monoxide (CO) poisonings has always been a challenging task due to the susceptibility to alterations of the optical state and degradation of blood samples during sampling, transport and storage, which highly affects the analysis with spectrophotometric methods. Methodological improvements are then required urgently because of increased reports of cases with discrepancies between results of the measured biomarker carboxyhemoglobin (COHb) and reported symptoms. Total blood CO (TBCO) measured chromatographically was thus proposed in a previous study as alternative biomarker to COHb. This approach was investigated in this study by comparing the two biomarkers and assessing the effects of various storage parameters (temperature, preservative, time, tube headspace (HS) volume, initial saturation level, freeze- and thaw- and reopening-cycles) over a period of one month. Results show that while for TBCO, concentrations are relatively stable over the observation period regardless of parameters such as temperature, time and HS volume, for COHb, concentrations are altered significantly during storage. Therefore, the use of TBCO as alternative biomarker for CO poisonings has been proposed, since it provides more valid results and is more stable even under non-optimal storage conditions. Additionally, it can be used to predict COHb in cases where sample degradation hinders optical measurement. Furthermore, a correction formula for COHb and TBCO is provided to be used in laboratories or circumstances where optimal storage or analysis is not possible, to obtain more accurate results.

Keywords: Blood analysis; COHb; Carbon monoxide poisoning; Carboxyhemoglobin; GC–MS; Storage conditions; TBCO.

PubMed Disclaimer

Publication types

LinkOut - more resources