Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2019 Dec 5;187(1):23.
doi: 10.1007/s00604-019-4027-z.

Electrochemical sensing of lead(II) by differential pulse voltammetry using conductive polypyrrole nanoparticles

Affiliations

Electrochemical sensing of lead(II) by differential pulse voltammetry using conductive polypyrrole nanoparticles

Tingting Xu et al. Mikrochim Acta. .

Abstract

An electrochemical sensor for Pb(II) is described that exploits (a) the outstanding adsorption ability of chitosan modified with quaternary ammonium groups (CQAS; cationic) and of lignosulfonate (LSN; anionic), and (b) the good electrical conductivity of polypyrrole nanoparticles (PPy NPs). A glassy carbon electrode (GCE) was modified with PPy NPs and polydopamine, and CQAS and LSN are used as dispersants in PPy. The modified GCE exhibits high selectivity and sensitivity for Pb(II) in the 0.1 to 50 μM concentration range, with a 55 nM detection limit (3σ method). The redox potentials for Pb(II) is around -0.55 V, and the sensor is not interfered by the presence of Hg(II) and Cu(II). The time dependent stability test showed that this sensor can maintain good reproducibility for one month. This sensor was applied to the determination of Pb(II) in wastewater samples. An electrochemical sensor for lead(II) is described that exploits the outstanding adsorption ability of chitosan that carries quaternary ammonium groups (CQAS), of lignosulfonate (LSN), and the good electrical conductivity of polypyrrole nanoparticles. CQAS and LSN are used as dispersants in PPy. The sensor exhibits high selectivity and sensitivity for Pb(II) in the range of 0.1 to 50 μM with a 55 nM detection limit.

Keywords: Adsorption ability; Chitosan quaternary ammonium salt; Electrochemical sensor; Lignosulfonate; Pb(II); Polypyrrole nanoparticles; Wastewater analysis.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Biosens Bioelectron. 2019 May 1;132:97-104 - PubMed
    1. Anal Chem. 2015;87(9):4933-40 - PubMed
    1. Anal Chem. 2018 Jan 16;90(2):1340-1347 - PubMed
    1. Biosens Bioelectron. 2018 Jan 15;99:571-577 - PubMed
    1. Talanta. 2017 Apr 1;165:231-239 - PubMed

Publication types

LinkOut - more resources