Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2020 Sep;46(9):e23-e31.
doi: 10.1097/DSS.0000000000002243.

Reliability of Periocular Anthropometry: A Comparison of Direct, 2-Dimensional, and 3-Dimensional Techniques

Affiliations
Comparative Study

Reliability of Periocular Anthropometry: A Comparison of Direct, 2-Dimensional, and 3-Dimensional Techniques

Yongwei Guo et al. Dermatol Surg. 2020 Sep.

Abstract

Background: Three-dimensional (3D) imaging has become increasingly popular in aesthetic surgery. However, few studies have emphasized its application in the periocular region.

Objective: To provide evidence supporting the reliability of generalizing periocular measurements obtained using caliper-derived direct anthropometry and 2-dimensional (2D) photogrammetry to 3D stereophotogrammetry.

Materials and methods: Periocular surfaces were captured using a stereophotogrammetry system for 46 normal Caucasian individuals. Twenty-two periocular variables were directly, 2-dimensionally, and 3-dimensionally measured. Reliability of these measurements was evaluated and compared with each other.

Results: The results revealed that, for direct (intra-rater reliability only), 2D, and 3D anthropometry, overall intra-rater and inter-rater intraclass correlation coefficient estimates were 0.88, 0.99 and 0.97, and 0.98 and 0.92, respectively; mean absolute differences were 0.84 mm, 0.26 and 0.36 units, and 0.35 and 0.67 units, respectively; technical error of measurement (TEM) estimates were 0.85 mm, 0.25 and 0.36 units, and 0.32 and 0.65 units, respectively; relative error measurement estimates were 6.46%, 1.69% and 2.74%, and 1.67% and 5.11%, respectively; and relative TEM estimates were 6.25%, 1.62% and 2.78%, and 2.12% and 5.12%, respectively.

Conclusion: Stereophotogrammetry and the authors' landmark location protocol yield very good reliability for a series of 2D and 3D measurements.

PubMed Disclaimer

References

    1. Lekakis G, Claes P, Hamilton GS III, Hellings PW. Three-dimensional surface imaging and the continuous evolution of preoperative and postoperative assessment in rhinoplasty. Facial Plast Surg 2016;32:88–94.
    1. Farkas LG. Accuracy of anthropometric measurements: past, present, and future. Cleft Palate Craniofac J 1996;33:10–8; discussion 19–22.
    1. Rootman DB, Karlin J, Moore G, Goldberg R. The effect of ptosis surgery on brow position and the utility of preoperative phenylephrine testing. Ophthalmic Plast Reconstr Surg 2016;32:195–8.
    1. Nakra T, Modjtahedi S, Vrcek I, Mancini R, et al. The effect of upper eyelid blepharoplasty on eyelid and brow position. Orbit 2016;35:324–7.
    1. Kokubo K, Katori N, Hayashi K, Sugawara J, et al. Evaluation of the eyebrow position after levator resection. J Plast Reconstr Aesthet Surg 2017;70:85–90.

Publication types

LinkOut - more resources