Ionizing Radiation Exposure in NICU
- PMID: 31833039
- PMCID: PMC7222152
- DOI: 10.1007/s12098-019-03126-9
Ionizing Radiation Exposure in NICU
Abstract
The authors prospectively studied ionizing radiation exposure in consecutive 107 very low birth weight (VLBW) neonates, admitted to their Level III neonatal intensive care unit (NICU). Number of X-rays, their indications and calculated dose of radiation were documented. Their mean birth weight (+SD) and gestational age (+SD) were 1077 (±219.8) g and 29.7 (+2.57) wk respectively. Extremely low birth weight (ELBW) neonates underwent significantly higher radiographs when compared with VLBW neonates; 7.5(5-13.25) vs. 2(1-6); p < 0.0001. ELBW neonates received 3 times higher dose of radiation, when compared with VLBW neonates; 139.4 μsv (81.6-256.15) vs. 46.6 μsv (14.4-115.7); p < 0.0001. Seven percent of ELBW neonates received >1msv radiation. Lifetime risk associated with high radiation exposure during neonatal period is unknown. Every effort should be taken to reduce number of radiographs. Imaging modalities without radiation exposure such as, point of care ultrasound should be used wherever possible.
Keywords: Neonatal intensive care unit; Preterm; Radiation exposure; Safety.
Conflict of interest statement
None.
References
-
- The 2007 recommendations of the International Commission on Radiological Protection. ICRP publication 103. Ann ICRP. 2007;37:1–332. - PubMed
-
- Lau KYK, Hui SCN, Cheung HM, Ng PC, Chu WCW. Cumulative radiation dose from radiography in preterm infants during hospitalisation. Hong Kong J Radiol. 2016;19:183–191. doi: 10.12809/hkjr1615349. - DOI
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources