Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Jun;29(3):157-167.
doi: 10.1080/08037051.2019.1658518. Epub 2019 Dec 13.

Central hemodynamics in relation to low-level environmental lead exposure

Affiliations
Free article

Central hemodynamics in relation to low-level environmental lead exposure

Cai-Guo Yu et al. Blood Press. 2020 Jun.
Free article

Abstract

Purpose: Arterial stiffness predicts cardiovascular complications. The association between arterial stiffness and blood lead (BL) remains poorly documented. We aimed to assess the association of central hemodynamic measurements, including pulse wave velocity (aPWV), with blood lead in a Flemish population.Materials and Methods: In this Flemish population study (mean age, 37.0 years; 48.3% women), 267 participants had their whole BL and 24-h urinary cadmium (UCd) measured by electrothermal atomic absorption spectrometry in 1985-2005. After 9.4 years (median), they underwent applanation tonometry to estimate central pulse pressure (cPP), the augmentation index (AI), pressure amplification (PA), and aPWV. The amplitudes of the forward (Pf) and backward (Pb) pulse waves and reflection index (RI) were derived by a pressure-based wave separation algorithm.Results: BL averaged 2.93 μg/dL (interquartile range, 1.80-4.70) and UCd 4.79 µg (2.91-7.85). Mean values were 45.0 ± 15.2 mm Hg for cPP, 24.4 ± 12.4% for AI, 1.34 ± 0.21 for PA, 7.65 ± 1.74 m/s for aPWV, 32.7 ± 9.9 mm Hg for Pf, 21.8 ± 8.4 mm Hg for Pb, and 66.9 ± 18.4% for RI. The multivariable-adjusted association sizes for a 2-fold higher BL were: +3.03% (95% confidence interval, 1.56, 4.50) for AI; -0.06 (-0.08, -0.04) for PA; 1.02 mm Hg (0.02, 2.02) for Pb; and 3.98% (1.71, 6.24) for RI (p ≤ .045). In 206 participants never on antihypertensive drug treatment, association sizes were +2.59 mm Hg (0.39, 4.79) for cPP and +0.26 m/s (0.03, 0.50) for aPWV. Analyses adjusted for co-exposure to cadmium were consistent.Conclusion: In conclusion, low-level environmental lead exposure possibly contributes to arterial stiffening and wave reflection from peripheral sites.

Keywords: arterial stiffness; central blood pressure; central hemodynamics; environmental medicine; lead.

PubMed Disclaimer

Publication types

MeSH terms