. 2020 Feb 15;30(1):010703.
doi: 10.11613/BM.2020.010703. Epub 2019 Dec 15.

Study of the preanalytical variables affecting the measurement of clinically relevant free-circulating microRNAs: focus on sample matrix, platelet depletion, and storage conditions

Affiliations

Study of the preanalytical variables affecting the measurement of clinically relevant free-circulating microRNAs: focus on sample matrix, platelet depletion, and storage conditions

Martina Faraldi et al. Biochem Med (Zagreb). .

Abstract

Introduction: Circulating microRNAs (miRNAs) are emerging as potential biomarkers. However, the lack of preanalytical and analytical standardization limits their use. The aim of this study was to determine the expression of different miRNAs in plasma according to different collection and storage conditions.

Materials and methods: Venous blood from 10 volunteers was collected in tubes spray-coated with dipotassium salt of ethylendiaminetetraacetic acid, either with (plasma-preparation tube, PPT) or without (K2EDTA) gel separator. Platelet-poor plasma (PPP) was also obtained from K2EDTA plasma. After storage under different conditions, miRNA-enriched total RNA was isolated from plasma and reverse transcribed. A panel of 179 miRNAs was assayed by quantitative polymerase chain reaction and the results were analysed by GenEx software. Detectability and stability of miRNAs were determined.

Results: The number of undetected miRNAs was: 18, 24, and 22 in PPT; 83, 43, and 20 in K2EDTA; and 76, 106, and 104 in PPP samples, for plasma immediately frozen at - 80°C and plasma stored for 24h at room temperature or 4°C, respectively. Circulating miRNA expression in PPT samples was not affected by storage delay or temperature, while the percentage of up- and down-regulated miRNA in K2EDTA and PPP samples ranged from 2%, and 1% to 7%, and 5%, respectively.

Conclusions: Sample matrix, temperature and delay in storage strongly influence the expression level of plasma miRNAs. Our results indicate PPT tubes as the most suitable matrix to improve total miRNA detectability and stability, independently of temperature.

Keywords: biomarkers; circulating microRNA; plasma; preanalytical phase.

PubMed Disclaimer

Conflict of interest statement

Potential conflict of interest: None declared.

References

    1. Morrow DA, de Lemos JA. Benchmarks for the assessment of novel cardiovascular biomarkers. Circulation. 2007;115:949–52. 10.1161/CIRCULATIONAHA.106.683110 - DOI - PubMed
    1. Hackl M, Heilmeier U, Weilner S, Grillari J. Circulating microRNAs as novel biomarkers for bone diseases - Complex signatures for multifactorial diseases? Mol Cell Endocrinol. 2016;432:83–95. 10.1016/j.mce.2015.10.015 - DOI - PubMed
    1. Ludwig N, Leidinger P, Becker K, Backes C, Fehlmann T, Pallasch C, et al. Distribution of miRNA expression across human tissues. Nucleic Acids Res. 2016;44:3865–77. 10.1093/nar/gkw116 - DOI - PMC - PubMed
    1. Mestdagh P, Hartmann N, Baeriswyl L, Andreasen D, Bernard N, Chen C, et al. Evaluation of quantitative miRNA expression platforms in the microRNA quality control (miRQC) study. Nat Methods. 2014;11:809–15. 10.1038/nmeth.3014 - DOI - PubMed
    1. Faraldi M, Gomarasca M, Banfi G, Lombardi G. Free circulating miRNA measurement in clinical settings: the still unresolved issue of the normalization. Adv Clin Chem. 2018;87:113–39. 10.1016/bs.acc.2018.07.003 - DOI - PMC - PubMed