Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Feb-Apr;80(2):151-155.
doi: 10.1080/00365513.2019.1703215. Epub 2019 Dec 14.

Thyroid stimulating hormone values of clinical decisions of hypothyroidism measurement by three different automated immunoassays

Affiliations

Thyroid stimulating hormone values of clinical decisions of hypothyroidism measurement by three different automated immunoassays

Bosa Mirjanic-Azaric et al. Scand J Clin Lab Invest. 2020 Feb-Apr.

Abstract

Background: An accurate measurement of serum thyroid stimulating hormone (TSH) is crucial for a thyroid disorder diagnosis and management. We compared the values of TSH between three automated immunoassays with aims to provide insights into variations in TSH levels that are important for a clinical decision: 2.50 mIU/L, 4.00 mIU/L and 10.00 mIU/L.Methods: We measured TSH with three different fully automated immunoassays: Abbott (Architect ci8200), Siemens (ADVIA Centaur XP) and Roche (Cobas e411). Serum was collected from 110 patients between August 2018 and January 2019. The results were compared using the Passing-Bablok regression method. Additionally, linear regression coefficients were calculated after logarithmic transformation of data.Results: Although all three regression coefficients were high (r2 > 0.98), the slopes from Passing-Bablok plots for the correlation of Abbott with either Roche or Siemens were merely 0.66 and 0.73, respectively. The slope for the correlation of Roche and Siemens was 1.11. Consecutively, the results obtained by the Roche and Siemens methods were proportionally higher than those obtained by the Abbott method (38% and 52%, respectively) at all measured ranges.Conclusions: Although immunoassays correlated among themselves, they cannot achieve the same values for clinical decisions for hypothyroidism (clinical requirements). Clinicians should be conscious of these limitations. A harmonisation of the methods is needed to meet clinical requirements and to enable appropriate clinical decisions in cases of hypothyroidism.Likewise, we suggest the introduction of borderline and high risk values of TSH for hypothyroidism depending on immunoassays to avoid misdiagnosis.

Keywords: Comparison immunoassays of TSH; clinical decisions of subclinical hypothyroidism.

PubMed Disclaimer

LinkOut - more resources