. 2019 May-Jun;16(3):173-180.
doi: 10.18502/fid.v16i3.1588. Epub 2019 Jun 29.

Microshear Bond Strength of Scotchbond Universal Adhesive to Primary and Permanent Dentin: A Six-Month in Vitro Study

Affiliations

Microshear Bond Strength of Scotchbond Universal Adhesive to Primary and Permanent Dentin: A Six-Month in Vitro Study

Masoud Fallahinejad Ghajari et al. Front Dent. 2019 May-Jun.

Abstract

Objectives: This study aimed to assess the microshear bond strength (MSBS) of Scotchbond Universal adhesive, used in self-etch and etch-and-rinse modes, to primary and permanent dentin at 24 hours and six months.

Materials and methods: A total of 88 composite micro-cylinders were divided into eight groups (n=11) as follows: (A) Etch-and-rinse, 24 hours, primary dentin; (B) Self-etch, 24 hours, primary dentin; (C) Etch-and-rinse, six months, primary dentin; (D) Self-etch, six months, primary dentin; (E) Etch-and-rinse, 24 hours, permanent dentin; (F) Self-etch, 24 hours, permanent dentin; (G) Etch-and-rinse, six months, permanent dentin; (H) Self-etch, six months, permanent dentin. The MSBS was measured by a testing machine at a crosshead speed of 0.5 mm/minute. Data were analyzed using three-way analysis of variance (ANOVA).

Results: The mean MSBS was 12.3±2.3 MPa in A, 18.8±4.1 MPa in B, 11.9±3.7 MPa in C, 16±2.9 MPa in D, 19.1±2.7 MPa in E, 22.8±4.1 MPa in F, 16.2±2.6 MPa in G, and 17.2±4.4 MPa in H. In the self-etch mode, the MSBS was significantly higher than that in the etch-and-rinse mode (P<0.001). The MSBS in permanent teeth was significantly higher than primary teeth (P<0.001). At six months, the MSBS significantly decreased in all groups (P<0.001).

Conclusion: The micro-shear bond strength of Scotchbond Universal adhesive decreases over time and depends on the type of tooth and the mode of application of the adhesive.

Keywords: Dentin Bonding Agents; Scotchbond; Shear Strength.

PubMed Disclaimer

Conflict of interest statement

CONFLICT OF INTEREST STATEMENT None declared.

Figures

Fig. 1.
Fig. 1.
Mean shear bond strength (MPa) in primary and permanent teeth with self-etch and etch-and-rinse modes of application at 24 hours and six months. Columns represent mean values and bars indicate standard deviation.

Similar articles

Cited by

References

    1. Miyazaki M, Tsubota K, Takamizawa T, Kurokawa H, Rikuta A, Ando S. Factors affecting the in vitro performance of dentin-bonding system. Jpn Dent Sci Rev. 2012. February;48(1):53–60.
    1. Wagner A, Wendler M, Petschelt A, Belli R, Lohbauer U. Bonding performance of universal adhesives in different etching modes. J Dent. 2014. July;42(7):800–7. - PubMed
    1. Marchesi G, Frassetto A, Mazzoni A, Apolonio F, Diolosà M, Cadenaro M, et al. Adhesive performance of a multi-mode adhesive system: 1-year in vitro study. J Dent. 2014. May;42(5):603–12. - PubMed
    1. Mena-Serrano A, Kose C, De Paula EA, Tay LY, Reis A, Loguercio AD, et al. A new universal simplified adhesive: 6-month clinical evaluation. J Esthet Restor Dent. 2013. February;25(1):55–69. - PubMed
    1. Perdigão J, Kose C, Mena-Serrano AP, De Paula EA, Tay LY, Reis A, et al. A new universal simplified adhesive: 18-month clinical evaluation. Oper Dent. 2014. Mar-Apr;39(2):113–27. - PubMed

LinkOut - more resources