Clinical Study of the Influence of Ambient Light Scanning Conditions on the Accuracy (Trueness and Precision) of an Intraoral Scanner

Affiliations

Clinical Study of the Influence of Ambient Light Scanning Conditions on the Accuracy (Trueness and Precision) of an Intraoral Scanner

Marta Revilla-León et al. J Prosthodont. 2020 Feb.

Abstract

Purpose: To quantify the impact of ambient lighting conditions on the accuracy (trueness and precision) of an intraoral scanner (IOS) when maxillary complete-arch and maxillary right quadrant digital scans were performed in a patient.

Material and methods: One complete dentate patient was selected. A complete maxillary arch vinyl polysiloxane impression was obtained and poured using Type IV dental stone. The working cast was digitized using a laboratory scanner (E4 Dental Scanner; 3Shape) and the reference standard tessellation language (STL file) was obtained. Two groups were created based on the extension of the maxillary digital scans performed namely complete-arch (CA group) and right quadrant (RQ) groups. The CA and RQ digital scans of the patient were performed using an IOS (TRIOS 3; 3Shape) with 4 lighting conditions chair light (CL), 10 000 lux, room light (RL), 1003 lux, natural light (NL), 500 lux, and no light (ZL), 0 lux. Ten digital scans per group at each ambient light settings (CL, RL, NL, and ZL) were consecutively obtained (n = 10). The STLR file was used to analyze the discrepancy between the digitized working cast and digital scans using MeshLab software. Kruskal-Wallis, one-way ANOVA, and pair-wise comparison were used to analyze the data.

Results: Significant difference in the trueness and precision values were found across different lighting conditions where RL condition obtained the lowest absolute error compared with the other lighting conditions tested followed by CL, NL, and ZL. On the CA group, RL condition also obtained the best accuracy values, CL and NL conditions performed closely and under ZL condition the mean error presented the highest values. On the RQ group, CL condition presented the lowest absolute error when compared with the other lighting conditions evaluated. A pair-wise multicomparison showed no significant difference between NL and ZL conditions. In all groups, the standard deviation was higher than the mean errors from the control mesh, indicating that the relative precision was low.

Conclusions: Light conditions significantly influenced on the scanning accuracy of the IOS evaluated. RL condition obtained the lowest absolute error value of the digital scans performed. The extension of the digital scan was a scanning accuracy influencing factor. The higher the extension of the digital scan performed, the lower the accuracy values obtained. Furthermore, ambient light scanning conditions influenced differently depending on the extension of the digital scans made.

Keywords: Intraoral scanners; accuracy; ambient light scanning conditions; influencing accuracy factors; trueness, precision.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Patzelt SB, Vonau S, Stampf S, et al: Assessing the feasibility and accuracy of digitizing edentulous jaws. J Am Dent Assoc 2013;144:914-920
    1. Flügge TV, Schlager S, Nelson K, et al: Precision of intraoral digital impressions with iTero and extraoral digitalization with iTero and a model scanner. Am J Orthod Dentofacial Orthop 2013;144:471-478
    1. Papaspyridakos P, Chen CJ, Gallucci GO, et al: Accuracy of implant impressions for partially and completely edentulous patients: a systematic review. Int J Oral Maxillofac Implants 2014;29:836-845
    1. De Luca Canto G, Pachêco-Pereira C, Lagravere MO, et al: Intra-arch dimensional measurement validity of laser-scanned digital dental models compared with the original plaster models: a systematic review. Orthod Craniofac Res 2015;18:65-76
    1. Al-Jubuori O, Azari A: An introduction to dental digitizers in dentistry. A systematic review. J Chem Pharm Res 2015;7:10-20

LinkOut - more resources