Late failure of a Nellix endoprosthesis treated with the t-Branch off-the-shelf multibranched stent graft

Affiliations
Case Reports

Late failure of a Nellix endoprosthesis treated with the t-Branch off-the-shelf multibranched stent graft

Antonio Lorido et al. J Vasc Surg Cases Innov Tech. .

Abstract

A 66-year-old man arrived at our emergency department 3 years after an endovascular aneurysm sealing procedure performed at another center. Computed tomography angiography showed distal migration of a Nellix endoprosthesis (Endologix, Irvine, Calif) and a posterior contained rupture. The left kidney was excluded by an occluded iliac-left renal bypass, which was performed at the time of the Nellix implantation because of unintended coverage. A t-Branch (Cook Medical, Bloomington, Ind) was implanted in an emergency, but the delivery caused disruption of the Nellix limb, requiring relining. Target vessels were bridged with VBX stents (W. L. Gore & Associates, Flagstaff, Ariz). The postoperative course was uneventful except for renal function impairment that was restored 2 weeks later.

Keywords: BEVAR; EVAS; Nellix; Type IA endoleak; t-Branch.

PubMed Disclaimer

Figures

Fig 1
Fig 1
A, Preoperative three-dimensional volume rendered image showing Nellix failure with type I endoleak from associated proximal evolution and endobag distal migration. B, Evidence of abdominal aortic aneurysm (AAA) contained rupture at L3 level and the occluded left renal bypass in a preoperative cross-sectional image.
Fig 2
Fig 2
A, The t-Branch device is delivered inside the Nellix endograft. B, The t-Branch device is released proximal to the right Nellix endobag.
Fig 3
Fig 3
Postoperative three-dimensional volume rendered image showing the correct t-Branch positioning with the branches' iliac axis patency and aneurysm exclusion.

References

    1. England A., Torella F., Fisher R.K., McWilliams R.G. Migration of the Nellix endoprosthesis. J Vasc Surg. 2016;64:306–312. - PubMed
    1. Donselaar E.J., Holden A., Zoethout A.C., Zeebregts C.J., Reijnen M.M. Feasibility and technical aspects of proximal Nellix-in-Nellix extension for late caudal endograft migration. J Endovasc Ther. 2017;24:210–217. - PubMed
    1. Donayre C.E., Zarins C.K., Krievins D.K., Holden A., Hill A., Calderas C. Initial clinical experience with a sac-anchoring endoprosthesis for aortic aneurysm repair. J Vasc Surg. 2011;53:574–582. - PubMed
    1. Böckler D., Holden A., Thompson M., Hayes P., Krievins D., de Vries J.P. Multicenter Nellix EndoVascular Aneurysm Sealing system experience in aneurysm sac sealing. J Vasc Surg. 2015;62:290–298. - PubMed
    1. Harrison S.C., Winterbottom A., Coughlin P., Hayes P., Boyle J.R. Editor's choice—mid-term migration and device failure following endovascular aneurysm sealing with the Nellix stent graft system—a single centre experience. Eur J Vasc Endovasc Surg. 2018;56:342–348. - PubMed

Publication types

LinkOut - more resources