Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2020 Apr;32(4):e13771.
doi: 10.1111/nmo.13771. Epub 2019 Dec 30.

Wireless motility capsule compared with scintigraphy in the assessment of diabetic gastroparesis

Affiliations
Clinical Trial

Wireless motility capsule compared with scintigraphy in the assessment of diabetic gastroparesis

Dag A Sangnes et al. Neurogastroenterol Motil. 2020 Apr.

Abstract

Background: Gastroparesis is a potentially severe late complication of diabetes mellitus. Today, delayed gastric emptying (GE) is mandatory for establishing the diagnosis. In this study, we compared wireless motility capsule (WMC) with gastric emptying scintigraphy (GES).

Methods: Seventy-two patients (49 women) with diabetes mellitus (59 type 1) and symptoms compatible with gastroparesis were prospectively included between 2014 and 2018. Patients were simultaneously examined with GES and WMC. Symptoms were assessed with the Patient Assessment of Upper Gastrointestinal Symptom Severity Index (PAGI-SYM) questionnaire. All patients were on intravenous glucose-insulin infusion during testing.

Key results: WMC and GES correlated r = .74, P < .001. Compared to GES, WMC at ordinary cutoff for delayed GE (300 minutes) had a sensitivity of 0.92, specificity 0.73, accuracy 0.80, and Cohen's kappa κ = 0.61 (P < .001). By receiver operating characteristics (ROC), the area under the curve was 0.95 (P < .001). A cutoff value for delayed GE of 385 minutes produced sensitivity 0.92, specificity 0.83, accuracy 0.86, and Cohen's kappa κ = 0.72 (P < .001). Inter-rater reliability for GE time with WMC was r = .996, κ = 0.97, both P < .001. There was no difference in symptom severity between patients with normal and delayed GE.

Conclusions & inferences: Our findings demonstrate the applicability of WMC as a reliable test to assess gastric emptying in diabetic gastroparesis showing very high inter-observer correlation. By elevating the cutoff value for delayed emptying from 300 to 385 minutes, we found higher specificity without reducing sensitivity.

Keywords: diabetes mellitus; gastric emptying; gastric emptying scintigraphy; gastroparesis; wireless motility capsule.

PubMed Disclaimer

References

REFERENCES

    1. Avalos DJ, Sarosiek I, Loganathan P, McCallum RW. Diabetic gastroparesis: current challenges and future prospects. Clin Exp Gastroenterol. 2018;11:347-363.
    1. Du YT, Rayner CK, Jones KL, Talley NJ, Horowitz M. Gastrointestinal symptoms in diabetes: prevalence, assessment, pathogenesis, and management. Diabetes Care. 2018;41(3):627-637.
    1. Phillips LK, Deane AM, Jones KL, Rayner CK, Horowitz M. Gastric emptying and glycaemia in health and diabetes mellitus. Nat Rev Endocrinol. 2015;11(2):112-128.
    1. Bharucha AE, Batey-Schaefer B, Cleary PA, et al. Delayed gastric emptying is associated with early and long- term hyperglycemia in Type 1 Diabetes Mellitus. Gastroenterology. 2015;149(2):330-339.
    1. Farmer AD, Pedersen AG, Brock B, et al. Type 1 diabetic patients with peripheral neuropathy have pan-enteric prolongation of gastrointestinal transit times and an altered caecal pH profile. Diabetologia. 2017;60(4):709-718.

Publication types

LinkOut - more resources