The effect of radial mismatch on radiographic glenoid loosening
- PMID: 31891027
- PMCID: PMC6928312
- DOI: 10.1016/j.jses.2019.09.007
The effect of radial mismatch on radiographic glenoid loosening
Abstract
Background: The ideal glenohumeral radial mismatch following anatomic total shoulder arthroplasty (TSA) remains ill defined, with biomechanical and clinical studies recommending a range between 4 and 10 mm. This study evaluates the effect of radial mismatch on the formation of radiolucent lines after TSA.
Methods: We evaluated 451 TSAs at a mean follow-up of 5.4 years. All TSAs were performed using a single implant system that allows radial mismatch between 3.4 and 7.7 mm. Shoulders were retrospectively evaluated for radiographic glenoid loosening according to the Lazarus score. Shoulders were evaluated according to radial mismatch: 3.4 mm in 23, 4.3 mm in 154, 5.1 mm in 72, 5.9 mm in 81, 6.7 mm in 103, and 7.7 mm in 18. Clinical outcome measures included range of motion and American Shoulder and Elbow Surgeons, University of California, Los Angeles, and Shoulder Pain and Disability Index scores.
Results: At similar follow-up times, all groups demonstrated a similar incidence of glenoid radiolucencies and similar mean Lazarus scores. Shoulders in female patients were more commonly treated with implant combinations resulting in 4.3, 5.9, and 7.7 mm of radial mismatch (P < .001). Improvements in range of motion and American Shoulder and Elbow Surgeons, University of California, Los Angeles, and Shoulder Pain and Disability Index scores were similar among all groups. Rates of reoperation secondary to glenoid loosening were similar among groups (P = .57). Moreover, the incidence of radiographic loosening (Lazarus grade 4 or 5) was similar among the groups (P = .22).
Discussion: Variation in mismatch between 3.4 and 7.7 mm did not affect the incidence of glenoid lucent lines or Lazarus score. This finding suggests that optimal radial mismatch may extend below 5.5 mm, as previously recommended by Walch et al, without affecting the incidence and grade of glenoid lucencies.
Keywords: Mismatch; glenoid loosening; loosening; outcomes; patient-reported outcomes; shoulder arthroplasty.
© 2019 The Authors.
Figures


Similar articles
-
Glenoid component lucencies are associated with poorer patient-reported outcomes following anatomic shoulder arthroplasty.J Shoulder Elbow Surg. 2019 Oct;28(10):1956-1963. doi: 10.1016/j.jse.2019.03.011. Epub 2019 Jun 13. J Shoulder Elbow Surg. 2019. PMID: 31202628
-
Outcomes of anatomic shoulder arthroplasty performed on B2 vs. A1 type glenoids.J Shoulder Elbow Surg. 2020 Dec;29(12):2571-2577. doi: 10.1016/j.jse.2020.03.050. Epub 2020 Jun 9. J Shoulder Elbow Surg. 2020. PMID: 33190757
-
Radiographic performance depends on the radial glenohumeral mismatch in total shoulder arthroplasty.BMC Musculoskelet Disord. 2020 Apr 3;21(1):206. doi: 10.1186/s12891-020-03219-z. BMC Musculoskelet Disord. 2020. PMID: 32245455 Free PMC article.
-
Cemented versus uncemented fixation of second-generation Trabecular Metal glenoid components: minimum 5-year outcomes.J Shoulder Elbow Surg. 2021 Apr;30(4):e147-e156. doi: 10.1016/j.jse.2020.07.025. Epub 2020 Aug 1. J Shoulder Elbow Surg. 2021. PMID: 32750528
-
Early results of augmented anatomic glenoid components.J Shoulder Elbow Surg. 2019 Jun;28(6S):S138-S145. doi: 10.1016/j.jse.2019.04.014. J Shoulder Elbow Surg. 2019. PMID: 31196508
Cited by
-
Glenoid Prosthesis Design Considerations in Anatomic Total Shoulder Arthroplasty.J Shoulder Elb Arthroplast. 2022 Dec 8;6:24715492221142856. doi: 10.1177/24715492221142856. eCollection 2022. J Shoulder Elb Arthroplast. 2022. PMID: 36518368 Free PMC article. Review.
-
Component Mix-Match for Anatomic Total Shoulder Arthroplasty Revision: A Case Report.Cureus. 2024 Dec 4;16(12):e75092. doi: 10.7759/cureus.75092. eCollection 2024 Dec. Cureus. 2024. PMID: 39759663 Free PMC article.
References
-
- Denard P.J., Raiss P., Sowa B., Walch G. Mid- to long-term follow-up of total shoulder arthroplasty using a keeled glenoid in young adults with primary glenohumeral arthritis. J Shoulder Elbow Surg. 2013;22:894–900. - PubMed
-
- Diop A., Maurel N., Grimberg J., Gagey O. Influence of glenohumeral mismatch on bone strains and implant displacements in implanted glenoïds. An in vitro experimental study on cadaveric scapulae. J Biomech. 2006;39:3026–3035. - PubMed
-
- Flurin P.-H., Marczuk Y., Janout M., Wright T.W., Zuckerman J., Roche C.P. Comparison of outcomes using anatomic and reverse total shoulder arthroplasty. Bull Hosp Jt Dis (2013) 2013;71(Suppl 2):101–107. - PubMed
-
- Fox T.J., Foruria A.M., Klika B.J., Sperling J.W., Schleck C.D., Cofield R.H. Radiographic survival in total shoulder arthroplasty. J Shoulder Elbow Surg. 2013;22:1221–1227. - PubMed
-
- Franklin J.L., Barrett W.P., Jackins S.E., Matsen F.A., 3rd Glenoid loosening in total shoulder arthroplasty. Association with rotator cuff deficiency. J Arthroplasty. 1988;3:39–46. - PubMed
LinkOut - more resources
Full Text Sources
Research Materials