The prevention of an anomalous chromatographic behavior and the resulting successful removal of viruses from monoclonal antibody with an asymmetric charge distribution by using a membrane adsorber in highly efficient, anion-exchange chromatography in flow-through mode
- PMID: 31894893
- DOI: 10.1002/btpr.2955
The prevention of an anomalous chromatographic behavior and the resulting successful removal of viruses from monoclonal antibody with an asymmetric charge distribution by using a membrane adsorber in highly efficient, anion-exchange chromatography in flow-through mode
Abstract
Anion exchange (AEX) chromatography in the flow-through mode is a widely employed purification process for removal of process/product-related impurities and exogenous/endogenous viruses from monoclonal antibodies (mAbs). The pH of the mobile phase for AEX chromatography is typically set at half a unit below the isoelectric point (pI) of each mAb (i.e., pI - 0.5) or lower and, in combination with a low ionic strength, these conditions are usually satisfactory for both the recovery of the mAb and removal of impurities. However, we have recently encountered a tight binding of mAb1 to AEX resins under these standard chromatographic conditions. This anomalous adsorption behavior appears to be an effect of the asymmetric charge distribution on the surface of the mAb1. We found that mAb1 did not bind to the AEX resins if the mobile phase has a much lower pH and higher ionic strength, but those conditions would not allow adequate virus removal. We predicted that the use of membrane adsorbers might provide effective mAb1 purification, since the supporting matrix has a network structure that would be less susceptible to interactions with the asymmetric charge distribution on the protein surface. We tested the Natriflo HD-Q AEX membrane adsorber under standard chromatographic conditions and found that mAb1 flowed through the membrane adsorber, resulting in successful separation from murine leukemia virus. This AEX membrane adsorber is expected to be useful for process development because mAbs can be purified under similar standard chromatographic conditions regardless of their charge distributions.
Keywords: anion exchange membrane adsorber; anomalous behavior; asymmetric charge distribution; monoclonal antibody; viral clearance.
© 2020 American Institute of Chemical Engineers.
References
REFERENCES
-
- Reichert JM. Antibodies to watch in 2017. MAbs. 2017;9:167-181.
-
- Vázquez-Rey M, Lang DA. Aggregates in monoclonal antibody manufacturing processes. Biotechnol Bioeng. 2011;108:1494-1508.
-
- Lai Y, Wang R, Chen X, Tang D, Hu Y, Cai J. Emerging trends and new developments in monoclonal antibodies: a scientometric analysis (1980-2016). Hum Vaccine Immunother. 2017;13:1388-1397.
-
- Kaplon H, Reichert JM. Antibodies to watch in 2019. MAbs. 2019;11:219-238.
-
- Zhang M, Lute S, Norling L, et al. A novel, Q-PCR based approach to measuring endogenous retroviral clearance by capture protein A chromatography. Biotechnol Bioeng. 2009;102:1438-1447.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Research Materials
Miscellaneous