Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1988 Nov;255(5 Pt 2):H1075-83.
doi: 10.1152/ajpheart.1988.255.5.H1075.

Pulmonary embolism: analysis of endothelial pore sizes in canine lung

Affiliations

Pulmonary embolism: analysis of endothelial pore sizes in canine lung

M I Townsley et al. Am J Physiol. 1988 Nov.

Abstract

The effect of glass-bead microemboli (diameter 100 micron, range 77-125 micron) in the absence of fibrinolysis inhibition on pulmonary hemodynamics and microvascular permeability was determined in anesthetized, microfilaria-free dogs acutely prepared for the collection of lung lymph. Pulmonary vascular resistance, pulmonary capillary pressure (Pc), lymph flow (QL), and the ratio of lymph (CL) to plasma (Cp) protein concentrations were measured after 0.2 (n = 4), 0.4 (n = 6), or 0.6 (n = 3) g/kg beads. In all cases, emboli increased resistance and QL severalfold (P less than 0.05), while CL/Cp remained unchanged. In part, the increase in QL could be attributed to an increase in Pc compared with control (12.4 +/- 2.2 vs. 6.7 +/- 0.6 mmHg, P less than 0.05). Furthermore, since the solvent-drag reflection coefficient (sigma f) for total proteins approaches the osmotic reflection coefficient (sigma d) at high QL, sigma d was estimated under these conditions with sigma f approximately equal to sigma d approximately equal to 1 - (CL/Cp)min. The sigma d was decreased (P less than 0.05) after 0.4 and 0.6 g/kg beads to 0.55 +/- 0.03 and 0.50 +/- 0.07, respectively, when compared with that in control lungs (sigma d = 0.62 +/- 0.02; Parker et al., Circ. Res. 48: 549-561, 1981). A pore-stripping analysis demonstrated that after emboli the pulmonary endothelial barrier could be described by a population of small (80 A) and large (350 A) pores. However, the number of large to small pores was 1:1,195, compared with 1:195 in control lungs, suggesting an increased contribution of extra-alveolar vessels upstream of the emboli.(ABSTRACT TRUNCATED AT 250 WORDS)

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources