Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Jan 3;15(1):1.
doi: 10.1186/s13000-019-0924-z.

Causes of misdiagnoses by thyroid fine-needle aspiration cytology (FNAC): our experience and a systematic review

Affiliations

Causes of misdiagnoses by thyroid fine-needle aspiration cytology (FNAC): our experience and a systematic review

Yanli Zhu et al. Diagn Pathol. .

Abstract

Objective: FNA is a simple, safe, cost-effective and accurate diagnostic tool for the initial screening of patients with thyroid nodules. The aims of this study were to determine the diagnostic utility of FNAC performed in our institution, assess the cytomorphologic features that contribute to diagnostic errors and propose improvement measures.

Methods: A total of 2781 FNACs were included in the study, and 1122 cases were compared with their histological diagnoses. We retrospectively reexamined our discordant (both false-negative and false-positive) cases and performed a systematic review of previous studies on causes of misdiagnoses.

Results: When DC V and DC VI were both considered cytologic-positive, the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and diagnostic accuracy were 98.3, 30.9, 94.9, 58.3 and 93.5%, respectively. If DC VI was considered cytologic-positive, the sensitivity, specificity, PPV, NPV and diagnostic accuracy of FNAC were 98.0, 84.0, 99.4, 58.3, and 97.5% respectively. The main cause of false-negative diagnoses was sampling error (13/15, 86.7%), while interpretation error led to the majority of the false-positive diagnoses (38/47, 80.9%). Overlapping cytological features in adenomatous hyperplasia, thyroiditis and cystic lesions were the major factors contributing to interpretation errors, while the size and number of nodules may have led to false-negative diagnoses because of heterogeneity and unsampled areas.

Conclusions: The sensitivity and PPV of thyroid FNAC in our institution were higher than those in the published data, while the specificity and NPV were lower. Regarding the FNA category DC V, a frozen section analysis during diagnostic lobectomy is necessary. Multiple passes should be performed in various parts of a large nodule or from different nodules to reduce the risk of false-negative findings. Cytopathologists should strengthen their criteria for the identification of adenomatous hyperplasia, thyroiditis and cystic lesions to avoid false-positive diagnoses. NIFTP has little effect on diagnostic accuracy and the distribution of diagnostic errors.

Keywords: False-negative; False-positive; Fine-needle aspiration cytology (FNAC); Noninvasive follicular thyroid neoplasm with papillary-like nuclear features (NIFTP); Thyroid.

PubMed Disclaimer

Conflict of interest statement

The authors declare that they have no competing interest.

References

    1. Hegedus L, Bonnema SJ, Bennedbaek FN. Management of simple nodular goiter: current status and future perspectives. Endocr Rev. 2003;24(1):102–132. doi: 10.1210/er.2002-0016. - DOI - PubMed
    1. Tamhane S, Gharib H. Thyroid nodule update on diagnosis and management. Clin Diabetes Endocrinol. 2016;2:17. doi: 10.1186/s40842-016-0035-7. - DOI - PMC - PubMed
    1. Cramer H. Fine-needle aspiration cytology of the thyroid: an appraisal. Cancer. 2000;90(6):325–329. doi: 10.1002/1097-0142(20001225)90:6<325::AID-CNCR1>3.0.CO;2-U. - DOI - PubMed
    1. Sheffield BS, Masoudi H, Walker B, Wiseman SM. Preoperative diagnosis of thyroid nodules using the Bethesda system for reporting thyroid cytopathology: a comprehensive review and meta-analysis. Expert Rev Endocrinol Metab. 2014;9(2):97–110. doi: 10.1586/17446651.2014.887435. - DOI - PubMed
    1. Malheiros DC, Canberk S, Poller DN, Schmitt F. Thyroid FNAC: Causes of false-positive results. Cytopathology. 2018;29(5):407–417. doi: 10.1111/cyt.12575. - DOI - PubMed

Publication types

MeSH terms