A vision 'bolt-on' increases the responsiveness of EQ-5D: preliminary evidence from a study of cataract surgery
- PMID: 31902023
- DOI: 10.1007/s10198-019-01156-w
A vision 'bolt-on' increases the responsiveness of EQ-5D: preliminary evidence from a study of cataract surgery
Abstract
Objectives: (1) To evaluate the effect of adding a vision dimension ('bolt-on') to the 5-level EQ-5D (EQ-5D-5L) and 3-level EQ-5D (EQ-5D-3L) on their responsiveness, and (2) to compare the responsiveness of a vision 'bolt-on' EQ-5D-3L (EQ-5D-3L + V) with SF-6D and Health Utilities Index Mark 3 (HUI3) to the benefit of cataract surgery.
Methods: Sixty-three patients were assessed before and after their cataract surgery using the EQ-5D-3L, EQ-5D-5L, SF-6D, HUI3, as well as a 3-level and a 5-level vision dimension. Preference-based indices were calculated using available value sets for EQ-5D-3L, EQ-5D-3L + V, EQ-5D-5L, SF-6D, and HUI3, and non-preference-based indices were calculated using the sum-score method for EQ-5D-5L and EQ-5D-5L + V (vision bolt-on EQ-5D-5L). Responsiveness was assessed using the standardized response mean (SRM) and F-statistic.
Results: Among preference-based indices, mean changes from pre to post-surgery in EQ-5D-3L + V and EQ-5D-3L indices were 0.031 and 0.018, respectively. The mean changes for EQ-5D-5L, SF-6D and HUI3 indices were 0.020, 0.012 and 0.105, respectively. The SRM (F-statistic) for EQ-5D-3L + V and EQ-5D-3L indices were 0.458 (13.2) and 0.098 (0.6), respectively. The responsiveness of EQ-5D-3L + V was better than EQ-5D-5L, SF-6D; the responsiveness of HUI3 was better than all other measures. Using non-preference-based indices, mean change for EQ-5D-5L + V and EQ-5D-5L were 0.067 and 0.017, respectively. The corresponding SRM (F-statistic) were 0.709 (31.7) and 0.295 (5.4).
Conclusions: Preliminary evidence from our study suggests that a vision 'bolt-on' may increase the responsiveness of EQ-5D-3L and EQ-5D-5L to change in health outcomes experienced by patients undergoing cataract surgery. In absence of the preference-based vision bolt-on EQ-5D-5L index, HUI3 was the most responsive measure.
Keywords: Bolt-on; Cataract; EQ-5D; Responsiveness; Vision.
References
-
- Longworth, L., Yang, Y., Young, T., Mulhern, B., Alava, M.H., Mukuria, C., Rowen, D., Tosh, J., Tsuchiya, A., Evans, P.: Use of generic and condition-specific measures of health-related quality of life in NICE decision-making: a systematic review, statistical modelling and survey. Health Technol. Assess. 18(9), 1–224 (2014). https://doi.org/10.3310/hta18090 - DOI - PubMed - PMC
-
- Janssen, M., Pickard, A.S., Golicki, D., Gudex, C., Niewada, M., Scalone, L., Swinburn, P., Busschbach, J.: Measurement properties of the EQ-5D-5L compared to the EQ-5D-3L across eight patient groups: a multi-country study. Qual. Life Res. 22(7), 1717–1727 (2013) - DOI
-
- Herdman, M., Gudex, C., Lloyd, A., Janssen, M., Kind, P., Parkin, D., Bonsel, G., Badia, X.: Development and preliminary testing of the new five-level version of EQ-5D (EQ-5D-5L). Qual. Life Res. 20(10), 1727–1736 (2011) - DOI
-
- Agborsangaya, C.B., Lahtinen, M., Cooke, T., Johnson, J.A.: Comparing the EQ-5D 3L and 5L: measurement properties and association with chronic conditions and multimorbidity in the general population. Health Qual. Life Outcomes 12(1), 74 (2014) - DOI
-
- NICE: Guide to the methods of technology appraisal 2013. https://www.nice.org.uk/process/pmg9/chapter/1-foreword (2013). Accessed 28 Feb 2018
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources