Point-of-Care Assessment of Hemostasis with a Love-Mode Surface Acoustic Wave Sensor

Affiliations

Point-of-Care Assessment of Hemostasis with a Love-Mode Surface Acoustic Wave Sensor

Xi Chen et al. ACS Sens. .

Abstract

Monitoring of the hemostasis status is essential for therapeutic anticoagulants, undergoing surgery, cardiovascular diseases, etc. Although the clinical values of conventional blood coagulation tests have been well demonstrated, these devices have limitations such as large and expensive equipment, excessive sample volumes, long turnaround times, and difficulty in miniaturization for point-of-care use. Here, we present a novel strategy to evaluate blood hemostasis using the single-port Love-mode surface acoustic wave (SLSAW) sensor. The SLSAW sensor was designed as a plug-and-play-type unit for disposable use and operated under the harmonic resonant mode to produce frequency response to the blood coagulation cascade. Compared with a quartz crystal microbalance, Lamb wave, and film bulk acoustic resonator, the frequency shift of SLSAW was significantly increased, ranging from approximately 8960 to 10 368 kHz, which indicated enhancement of the signal-to-noise ratio. To demonstrate the feasibility of the SLSAW, studies were carried out to examine the effects of temperature and clotting reagents on coagulation times and kinetics. Activated partial thromboplastin times of plasma were validated by comparing with SYSMEX CA-7000 with the correlation (R2) as 0.996. In terms of coagulation kinetics, reaction time, clot formation time, maximum frequency shift, and clot formation rate of whole blood correlated well with corresponding parameters of the standard thromboelastography (TEG) analyzer (R2 = 0.9942, 0.9868, 0.9712, and 0.9939, respectively). The SLSAW sensor, with the advantages of low cost, small size, little sample consumption (1 μL), disposable use, and simple operation, is a promising tool for point-of-care diagnosis of hemostasis.

Keywords: Love wave; blood coagulation; hemostasis; point of care; surface acoustic wave; viscoelasticity.