Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Jun;91(6):1242-1250.
doi: 10.1016/j.gie.2019.12.048. Epub 2020 Jan 10.

Deep learning algorithm detection of Barrett's neoplasia with high accuracy during live endoscopic procedures: a pilot study (with video)

Affiliations

Deep learning algorithm detection of Barrett's neoplasia with high accuracy during live endoscopic procedures: a pilot study (with video)

Albert J de Groof et al. Gastrointest Endosc. 2020 Jun.

Abstract

Background and aims: We assessed the preliminary diagnostic accuracy of a recently developed computer-aided detection (CAD) system for detection of Barrett's neoplasia during live endoscopic procedures.

Methods: The CAD system was tested during endoscopic procedures in 10 patients with nondysplastic Barrett's esophagus (NDBE) and 10 patients with confirmed Barrett's neoplasia. White-light endoscopy images were obtained at every 2-cm level of the Barrett's segment and immediately analyzed by the CAD system, providing instant feedback to the endoscopist. At every level, 3 images were evaluated by the CAD system. Outcome measures were diagnostic performance of the CAD system per level and per patient, defined as accuracy, sensitivity, and specificity (ground truth was established by expert assessment and corresponding histopathology), and concordance of 3 sequential CAD predictions per level.

Results: Accuracy, sensitivity, and specificity of the CAD system in a per-level analyses were 90%, 91%, and 89%, respectively. Nine of 10 neoplastic patients were correctly diagnosed. The single lesion not detected by CAD showed NDBE in the endoscopic resection specimen. In only 1 NDBE patient, the CAD system produced false-positive predictions. In 75% of all levels, the CAD system produced 3 concordant predictions.

Conclusions: This is one of the first studies to evaluate a CAD system for Barrett's neoplasia during live endoscopic procedures. The system detected neoplasia with high accuracy, with only a small number of false-positive predictions and with a high concordance rate between separate predictions. The CAD system is thereby ready for testing in larger, multicenter trials. (Clinical trial registration number: NL7544.).

PubMed Disclaimer

Comment in

LinkOut - more resources