Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Apr 10:712:136494.
doi: 10.1016/j.scitotenv.2020.136494. Epub 2020 Jan 3.

Traditional and emerging organophosphate esters (OPEs) in indoor dust of Nanjing, eastern China: Occurrence, human exposure, and risk assessment

Affiliations

Traditional and emerging organophosphate esters (OPEs) in indoor dust of Nanjing, eastern China: Occurrence, human exposure, and risk assessment

Luming Zhao et al. Sci Total Environ. .

Abstract

Here, fifteen OPEs were investigated in n = 50 floor dust samples collected from six types of indoor spaces in Nanjing, eastern China, in the year 2018. Ten OPEs, including tris(2-chloroethyl) phosphate (TCEP), tris(2-chloroisopropyl) phosphate (TCIPP), tris(1,3-dichloro-isopropyl) phosphate (TDCIPP), tris(2-ethylhexyl) phosphate (TEHP), tris(2-butoxyethyl) phosphate (TBOEP), 2-ethylhexyl-diphenyl phosphate (EHDPP), triphenyl phosphate (TPHP), tris(methyl-phenyl) phosphate (TMPP), 4-biphenylyl diphenyl phosphate (4-BPDP) and tris(2-biphenylyl) phosphate (TBPP), were detected in at least one of the analyzed samples (>method limits of quantification). Regardless of indoor spaces, EHDPP (34% of Σ8OPEs, mean: 1.43 μg/g) and TDCIPP (19%, 0.81 μg/g) were the ascendant OPEs in indoor floor dust. 4-BPDP and TBPP were detectable in indoor floor dust samples, but at relatively low detection frequencies with 2% and 10%, respectively. Various indoor microenvironments exhibited different pollution characteristics of OPEs. Floor dust collected from electronic product maintenance centers contained the richest OPE contaminants with highest mean Σ8OPEs concentration of 7.92 μg/g. On the basis of measured Σ10OPEs concentrations in dust sample, we estimated daily intake via floor dust ingestion to be 1.37, 0.75 and 1.24 ng/kg BW/day for electronic engineers, undergraduates, and graduate students under mean-exposure scenario, respectively. Overall, our study reported the occurrence of 4-BPDP and TBPP in environmental samples for the first time, and demonstrated that indoor floor dust ingestion exposure does values were far less than reference dosage values of oral toxicity proposed by United States Environmental Protection Agency (USEPA) Integrated Risk Information System.

Keywords: 4-Biphenylyl diphenyl phosphate (4-BPDP); Dust ingestion assessment; Indoor floor dust; Organophosphate esters (OPEs); Tris(2-biphenylyl) phosphate (TBPP).

PubMed Disclaimer

Conflict of interest statement

Declaration of competing interest The authors declare that they have no known competing financial interest or personal relationships that could have appeared to influence the work reported in this paper.

LinkOut - more resources