Residential water heater cleaning and occurrence of Legionella in Flint, MI
- PMID: 31940510
- DOI: 10.1016/j.watres.2019.115439
Residential water heater cleaning and occurrence of Legionella in Flint, MI
Abstract
After the Federal emergency in Flint, MI was declared in early 2016 in response to elevated lead-in-water and incidence of Legionnaires' disease, concerns arose that contaminants in residential water heaters could continue to contribute to poor quality tap water. Here, a comprehensive field survey of residential water heaters (n = 30) and associated water quality was conducted and the subsequent effects of an aggressive manual water heater clean-out was determined, including draining the tank and removing sediments via brushing and flushing. Before cleaning, inorganics accumulated in the tank sediments did not serve as a source of metals measured at hot water outlets. After cleaning, hardness- (calcium, magnesium, silica) and corrosion-associated inorganics (lead, iron, copper, aluminum, zinc) decreased by 64% in samples from sediment cleanout drain valves. Culturable L. pneumophila was only detected in 1 home (3.3%) prior to cleaning and 2 homes (6.7%) after cleaning, thus quantitative polymerase chain reaction was used to quantify potential effects on unculturable strains despite the limitation of differentiating live and dead cells. After the cleaning protocol, Legionella spp. and L. pneumophila gene numbers decreased or remained non-detectable in 83% and 98% of samples, respectively. Homes with less than 0.4 mg/L influent free chlorine tended to have quantifiable Legionella spp. gene numbers in water entering the home and had elevated L. pneumophila and Legionella spp. gene numbers throughout the home plumbing. Also, Legionella spp. and L. pneumophila gene numbers were highest for water heaters set at or below ∼42 °C and significantly decreased >51 °C, consistent with Legionella's preferred temperature range. Examination of the only home that had culturable L. pneumophila both before and after the cleaning protocol revealed that the organism was culturable from several sample locations throughout the home, including in water representative of the water main. Notably, the home was located in close proximity to McLaren Hospital, where an outbreak of Legionnaires disease was reported, and the water heater had a setpoint within the Legionella growth range of 44.2 °C. Considering that other factors were more strongly associated with Legionella occurrence and water heater sediment was not detectably mobilizing to tap water, it was concluded that water heater cleaning had some benefits, but was not an overarching factor contributing to possible human health risks.
Keywords: Flint; Flushing; Legionella; MI; Risk factors; Sediment; Water heater.
Copyright © 2020 Elsevier Ltd. All rights reserved.
Conflict of interest statement
Declaration of competing interest The authors declare that they have no known competing financial interest or personal relationships that could have appeared to influence the work reported in this paper.
Similar articles
-
Water heater temperature set point and water use patterns influence Legionella pneumophila and associated microorganisms at the tap.Microbiome. 2015 Dec 1;3:67. doi: 10.1186/s40168-015-0134-1. Microbiome. 2015. PMID: 26627188 Free PMC article.
-
Legionella pneumophila occurrence in drinking water supplied by private wells.Lett Appl Microbiol. 2020 Apr;70(4):232-240. doi: 10.1111/lam.13273. Epub 2020 Jan 24. Lett Appl Microbiol. 2020. PMID: 31904109
-
Legionella infection risk from domestic hot water.Emerg Infect Dis. 2004 Mar;10(3):457-64. doi: 10.3201/eid1003.020707. Emerg Infect Dis. 2004. PMID: 15109413 Free PMC article.
-
Microbiological investigations on a nosocomial case of Legionella pneumophila pneumonia associated with water birth and review of neonatal cases.Infez Med. 2004 Mar;12(1):69-75. Infez Med. 2004. PMID: 15329532 Review.
-
Confirming the Presence of Legionella pneumophila in Your Water System: A Review of Current Legionella Testing Methods.J AOAC Int. 2021 Aug 20;104(4):1135-1147. doi: 10.1093/jaoacint/qsab003. J AOAC Int. 2021. PMID: 33484265 Free PMC article. Review.
Cited by
-
Considerations for large building water quality after extended stagnation.AWWA Water Sci. 2020 Jul-Aug;2(4):e1186. doi: 10.1002/aws2.1186. Epub 2020 Aug 6. AWWA Water Sci. 2020. PMID: 32838226 Free PMC article. Review.
-
Vertical stratification of the water microbiome in an electric water heater tank: implications for premise plumbing opportunistic pathogens.J Water Health. 2024 Dec;22(12):2346-2357. doi: 10.2166/wh.2024.265. Epub 2024 Nov 21. J Water Health. 2024. PMID: 39733360 Free PMC article.
-
Critical Review: Propensity of Premise Plumbing Pipe Materials to Enhance or Diminish Growth of Legionella and Other Opportunistic Pathogens.Pathogens. 2020 Nov 17;9(11):957. doi: 10.3390/pathogens9110957. Pathogens. 2020. PMID: 33212943 Free PMC article. Review.
-
Assessing residential activity in a home plumbing system simulator: monitoring the occurrence and relationship of major opportunistic pathogens and phagocytic amoebas.Front Microbiol. 2023 Oct 17;14:1260460. doi: 10.3389/fmicb.2023.1260460. eCollection 2023. Front Microbiol. 2023. PMID: 37915853 Free PMC article.
-
Water Heater Type, Temperature Setting, Operational Conditions, and Insulation Affect Ecological Niches for Legionella Growth.ACS ES T Water. 2024 Dec 23;5(1):377-386. doi: 10.1021/acsestwater.4c00894. eCollection 2025 Jan 10. ACS ES T Water. 2024. PMID: 39816977 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous