A Surface Electromyogram Evaluation of the Postural Freedom Effects in Laparoscopic Surgery

Free article

A Surface Electromyogram Evaluation of the Postural Freedom Effects in Laparoscopic Surgery

Horacio M Pace-Bedetti et al. Annu Int Conf IEEE Eng Med Biol Soc. 2019 Jul.
Free article

Abstract

It has been demonstrated that laparoscopic procedures benefit patients in terms of recovery time, exposure to infections and trauma. Nevertheless, it increases the number of problems for the surgeons, including the frequency and duration of awkward postures for surgeons. The repetition of these movements is considered the main cause for musculoskeletal disorders in surgeons' upper limbs. The goal of this study is to evaluate the muscular activity and muscular fatigue effect produced by both, a conventional instrument and an instrument provided with the Postural Freedom (PF) feature; which consists in a ball socket articulation that allows a variable handle-to-shaft angle, on a conventional laparoscopic pistol-grip handle. Seventeen participants were evaluated during a static simulation using both instruments. Surface electromyography was used to compare the instruments in terms of muscular activity in each target position and muscular fatigue produced in the muscles trapezius, deltoids, biceps, and flexor carpi radialis. Trapezius and deltoids were the muscles most affected. Entrance and exit targets and targets facing the participants showed the higher muscular activity values. The PF prototype reduced muscular activity in all the muscles and in the majority of the target positions showing a reduction greater than 70% of the activity required by the trapezius and deltoid muscles in comparison to the conventional tool. Muscular fatigue was produced by both instruments but it presented lower frequency values with PF prototype. The results indicated that the use of conventional instruments impacts negatively on muscular activity during laparoscopic procedures, in terms of positions adopted. The PF feature in laparoscopic instrumentation reduced the muscular activity and also decreased the signals of muscular fatigue in the muscles evaluated in comparison with the conventional tool.