Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2020 Mar;31(3):647-657.
doi: 10.1111/jce.14359. Epub 2020 Jan 24.

Additional benefits of nonconventional modalities of cardiac resynchronization therapy using His bundle pacing

Affiliations
Comparative Study

Additional benefits of nonconventional modalities of cardiac resynchronization therapy using His bundle pacing

Giovanni Coluccia et al. J Cardiovasc Electrophysiol. 2020 Mar.

Abstract

Introduction: Dyssynchrony persists in many patients despite cardiac resynchronization therapy (CRT). Aim of this proof-of-concept study was to achieve better CRT, with a QRS approximating the normal width and axis, by using His bundle pacing (HBP) and nonconventional pacing configurations.

Methods and results: In 20 patients with CRT indications, we performed an acute intrapatient comparison between conventional biventricular (CONV) and three nonconventional pacing modalities: HBP alone, His bundle, and coronary sinus pacing (HBP + CS), and HBP + CS plus right ventricular pacing (TRIPLE). Electrical dyssynchrony was assessed by means of QRS width and axis; "quasi-normal" axis meant an R/S ratio ≥ 1 in leads I and V6 and ≤1 in V1. Mechanical dyssynchrony was assessed by speckle tracking echocardiography. QRS width was 153 ± 18 ms on CONV, shortened to 137 ± 16 ms on HBP + CS (P = .001) and to 130 ± 14 ms on TRIPLE (P = .001), while it remained unchanged on HBP (159 ± 32 ms; P = .17). The rate of patients with "quasi-normal" axis was 5% on CONV, and increased to 90% on HBP (P = .0001), to 63% on HBP + CS (P = .001), and to 44% on TRIPLE (P = .02). On radial strain analysis, the time-to-peak difference between anteroseptal and posterolateral segments was 143 ± 116 ms on CONV, shortened to 121 ± 127 ms on HBP (P = .79), to 67 ± 70 ms on HBP + CS (P = .02), and to 76 ± 55 ms on TRIPLE (P = .05). On discharge, HBP was chosen in 15% of patients, HBP + CS in 55%, and TRIPLE in 30%; CONV was never chosen.

Conclusion: Nonconventional modalities of CRT provide acute additional electrical and mechanical resynchronization. An interpatient variability exists.

Keywords: His bundle pacing; cardiac resynchronization therapy; dyssynchrony; heart failure; speckle tracking.

PubMed Disclaimer

References

REFERENCES

    1. Daubert JC, Saxon L, Adamson PB, et al. 2012 EHRA/HRS expert consensus statement on cardiac resynchronization therapy in heart failure: implant and follow-up recommendations and management. Heart Rhythm. 2012;9(9):1524-1576.
    1. Mullens W, Grimm RA, Verga T, et al. Insights from a cardiac resynchronization optimization clinic as part of a heart failure disease management program. J Am Coll Cardiol. 2009;53:765-773.
    1. Barold S, Herweg B. Usefulness of the 12-lead electrocardiogram in the follow-up of patients with cardiac resynchronization devices. Part I. Cardiol J. 2011;18:476-486.
    1. Molhoek SG, Bax JJ, Bleeker GB, et al. Long-term follow-up of cardiac resynchronization therapy in patients with end-stage heart failure. J Cardiovasc Electrophysiol. 2005;16:701-707.
    1. Ypenburg C, Schalij MJ, Bleeker GB, et al. Impact of viability and scar tissue on response to cardiac resynchronization therapy in ischaemic heart failure patients. Eur Heart J. 2007;28:33-41.

Publication types

MeSH terms