[Contact allergy due to insulin pumps and glucose sensor systems]
- PMID: 31965206
- DOI: 10.1007/s00105-019-04533-x
[Contact allergy due to insulin pumps and glucose sensor systems]
Abstract
The design and development of insulin pumps and various glucose sensor systems has an enormous impact on life quality of diabetic patients. Surveillance and therapy of diabetes has improved due to the new diabetic devices, which are affixed to the patients' skin for several days. Since their introduction, irritant and allergic contact dermatitis have been frequently reported. Patients often acquire contact sensitization to isobornyl acrylate, N,N-dimethylacrylamide or formerly to 2‑ethyl-cyanoacrylate. These contact allergens were found in the patch, in the glue to affix the box on the patch or in the casing of the system itself. Development of contact allergy to substances of these systems may result in the need to abandon modern diabetic devices.
Keywords: Contact hypersensitivity; Glucose sensors; Insulin infusion systems; Insulin-dependent diabetes; Isobornyl acrylate.
Similar articles
-
Allergic contact dermatitis caused by glucose sensors and insulin pumps: A full review: Part 1: Sensors and pumps, adverse cutaneous reactions, allergens, and diabetes devices causing allergic contact dermatitis.Contact Dermatitis. 2025 Feb;92(2):87-112. doi: 10.1111/cod.14698. Epub 2024 Nov 26. Contact Dermatitis. 2025. PMID: 39600106 Free PMC article. Review.
-
Allergic contact dermatitis caused by glucose sensors and insulin pumps: A full review: Part 2. Case reports and case series, clinical features, patch test procedures, differentiation from irritant dermatitis, management of allergic patients and (proposed) legislation.Contact Dermatitis. 2025 Mar;92(3):164-175. doi: 10.1111/cod.14697. Epub 2024 Nov 26. Contact Dermatitis. 2025. PMID: 39600134 Free PMC article. Review.
-
Allergic contact dermatitis caused by medical devices for diabetes patients: A review.Contact Dermatitis. 2018 Dec;79(6):331-335. doi: 10.1111/cod.13120. Epub 2018 Sep 28. Contact Dermatitis. 2018. PMID: 30264920 Review.
-
Adverse cutaneous reaction to diabetic glucose sensors and insulin pumps: Irritant contact dermatitis or allergic contact dermatitis?Contact Dermatitis. 2020 Jul;83(1):25-30. doi: 10.1111/cod.13529. Epub 2020 May 4. Contact Dermatitis. 2020. PMID: 32212168
-
Allergic contact dermatitis in pediatric patients with type 1 diabetes: An emerging issue.Diabetes Res Clin Pract. 2020 Apr;162:108089. doi: 10.1016/j.diabres.2020.108089. Epub 2020 Feb 19. Diabetes Res Clin Pract. 2020. PMID: 32087268
Cited by
-
Allergic contact dermatitis caused by glucose sensors and insulin pumps: A full review: Part 1: Sensors and pumps, adverse cutaneous reactions, allergens, and diabetes devices causing allergic contact dermatitis.Contact Dermatitis. 2025 Feb;92(2):87-112. doi: 10.1111/cod.14698. Epub 2024 Nov 26. Contact Dermatitis. 2025. PMID: 39600106 Free PMC article. Review.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources