Case Reports
. 2019;26(6):790-792.
doi: 10.5603/CJ.2019.0115.

Feasibility of in-house rapid prototyping of cardiovascular three-dimensional models for planning and training non-standard interventional procedures

Affiliations
Case Reports

Feasibility of in-house rapid prototyping of cardiovascular three-dimensional models for planning and training non-standard interventional procedures

Jarosław Meyer-Szary et al. Cardiol J. 2019.
No abstract available

Keywords: 3D printing; anatomy models; cardiac surgery; interventional cardiology; medical education; procedure simulation; rapid prototyping; treatment simulation.

PubMed Disclaimer

Conflict of interest statement

Conflict of interest: None declared

Figures

Figure 1
Figure 1
A. Volume rendering of the computed tomography left antero-lateral aspect; the blue area represents the thrombotic mass with numerous calcifications on the surface; B. Model I, active aneurism (*), bypass-graft (BG) and the compressed left pulmonary artery (LPA) are clearly visible; C. Model I including the thrombotic part of the aneurismal mass (Th) made separately of translucent material; D, E. Model II — region of interest, hollow vessels for simulation and training made of semi-flexible material with 1.2 mm wall thickness to ensure model printability and durability; F. The simulated procedure from the femoral access, it was difficult to pass through the 120 degree angle to reach the implantation site; G. The simulated procedure from the left radial access, a straight route to the aneurism, the device is introduced to the implantation site; H. The treatment procedure — the sheath introduced from left radial site, secondary access from femoral to inject contrast medium. ADO II at the implantation site; I. The treatment procedure — the sheath introduced from left radial site, secondary access from femoral to inject contrast medium. ADO II at the implantation site.

Comment in

References

    1. Valverde I, Gomez G, Coserria JF, et al. 3D printed models for planning endovascular stenting in transverse aortic arch hypoplasia. Catheter Cardiovasc Interv. 2015;85(6):1006–1012. doi: 10.1002/ccd.25810. - DOI - PubMed
    1. Sabiniewicz R, Meyer-Szary J, Potaż P, et al. Melody valve implantation pre-procedural planning using custom-made 3D printed model of the region of interest. Adv Interv Cardiol. 2018;14(2):210–211. doi: 10.5114/aic.2018.76419. - DOI - PMC - PubMed

Publication types

MeSH terms