Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Mar 4;31(3):479-487.
doi: 10.1021/jasms.9b00110. Epub 2020 Jan 30.

Ganglioside Detection from Formalin-Fixed Human Brain Tissue Utilizing MALDI Imaging Mass Spectrometry

Affiliations

Ganglioside Detection from Formalin-Fixed Human Brain Tissue Utilizing MALDI Imaging Mass Spectrometry

Aaron Harris et al. J Am Soc Mass Spectrom. .

Abstract

Matrix assisted laser desorption ionization (MALDI) imaging mass spectrometry (IMS) is used to perform mass spectrometric analysis directly on biological samples providing visual and anatomical spatial information on molecules within tissues. A current obscuration of MALDI-IMS is that it is largely performed on fresh frozen tissue, whereas clinical tissue samples stored long-term are fixed in formalin, and the fixation process is thought to cause signal suppression for lipid molecules. Studies have shown that fresh frozen tissue sections applied with an ammonium formate (AF) wash prior to matrix application in the MALDI-IMS procedure display an increase in observed signal intensity and sensitivity for lipid molecules detected within the brain while maintaining the spatial distribution of molecules throughout the tissue. In this work, we investigate the viability of formalin-fixed tissue imaging in a clinical setting by comparing MALDI data of fresh frozen and postfixed rat brain samples, along with postfixed human brain samples washed with AF to assess the capabilities of ganglioside analysis in MALDI imaging of formalin-fixed tissue. Results herein demonstrate that MALDI-IMS spectra for gangliosides, including GM1, were significantly enhanced in fresh frozen rat brain, formalin-fixed rat brain, and formalin-fixed human brain samples through the use of an AF wash. Improvements in MALDI-IMS image quality were demonstrated, and the spatial distribution of molecules was retained. Results indicate that this method will allow for the analysis of gangliosides from formalin-fixed clinical samples, which can open additional avenues for neurodegenerative disease research.

Keywords: MALDI-MSI; ammonium formate; formalin fixation; gangliosides; human brain tissue.

PubMed Disclaimer

LinkOut - more resources