Reducing contamination of midstream urine samples through standardized collection processes: a best practice implementation project
- PMID: 31972684
- DOI: 10.11124/JBISRIR-D-19-00149
Reducing contamination of midstream urine samples through standardized collection processes: a best practice implementation project
Abstract
Objective: The objective of this project is to decrease the rates of midstream urine sample contamination through standardization of evidence-based techniques among nurses.
Introduction: Urinary tract infection is a prevalent health problem worldwide. The diagnosis and treatment of urinary tract infection depend on a thorough physical examination and the results of an uncontaminated midstream specimen of urine. However, improper techniques used in the collection often cause sample contamination, leading to delayed diagnosis and the use of inappropriate antibiotics for treatment. As nurses are at the forefront of care delivery, they are involved in reducing the rates of midstream urine sample contamination. Thus, the use of an evidence-based approach to standardize collection of midstream urine culture is crucial for the provision of higher-quality patient care.
Methods: Education sessions were delivered to the nurses and an evidence-informed standardized patient education leaflet was crafted by the project team for implementation. With a sample size of 30 nurses and patients, the project took place in a 21-bed adult surgical ward in a hospital in Singapore. The JBI Practical Application of Clinical Evidence System (JBI PACES) and Getting Research into Practice (GRiP) programs were used to implement the evidence-based project. The project was implemented in three phases from October 2018 to January 2019. A standardized audit tool devised from JBI PACES was used for the audits in this project. The rates of midstream urine specimen contamination and the knowledge of nurses were also monitored.
Results: The baseline audit revealed that the nursing staff required educational sessions to improve their knowledge of midstream urine sample collection. Aside from criteria 1,3 and 4, the remaining criteria achieved compliance of more than 80%. The criteria below 80% compliance became the main focus of the project interventions. At follow-up cycle 1, all criteria achieved at least 80% compliance except criteria 4 and 5, which achieved 73% and 69% compliance, respectively. At the three-month post implementation audit, all criteria achieved a compliance rate of at least 80%. Fisher's exact test was carried out, and statistical significance of the results was achieved (p < 0.001) when compared to baseline audit. The rates of midstream urine specimen contamination also significantly decreased from 40% at the baseline audit to 20% at the third-month post implementation audit. Nurses' knowledge markedly improved as measured by the three-question quiz.
Conclusion: This evidence-based implementation project highlights the effectiveness of the JBI PACES and GRiP processes for initiating best practice within a nursing environment. The use of JBI best-practice recommendations to standardize methods for midstream urine specimen collection effectively reduced the rates of midstream urine contamination.
Similar articles
-
Patient handover in the oncology setting: an evidence utilisation project.Int J Evid Based Healthc. 2012 Dec;10(4):369-76. doi: 10.1111/j.1744-1609.2012.00280.x. Int J Evid Based Healthc. 2012. PMID: 23173661
-
Improving the accuracy of fluid intake charting through patient involvement in an adult surgical ward: a best practice implementation project.JBI Database System Rev Implement Rep. 2018 Aug;16(8):1709-1719. doi: 10.11124/JBISRIR-2017-003683. JBI Database System Rev Implement Rep. 2018. PMID: 30113551
-
Accurate falls risk assessment and interventions for preventing falls in patients in the acute care setting within a private hospital in a large capital city: a best practice implementation project.JBI Database System Rev Implement Rep. 2015 Sep;13(9):386-406. doi: 10.11124/jbisrir-2015-2089. JBI Database System Rev Implement Rep. 2015. PMID: 26470676
-
Assessment and management of cough among patients with lung cancer in a radiotherapy department in China: a best practice implementation project.JBI Database System Rev Implement Rep. 2019 Nov;17(11):2390-2400. doi: 10.11124/JBISRIR-2017-004001. JBI Database System Rev Implement Rep. 2019. PMID: 31335559
-
Effectiveness of Preanalytic Practices on Contamination and Diagnostic Accuracy of Urine Cultures: a Laboratory Medicine Best Practices Systematic Review and Meta-analysis.Clin Microbiol Rev. 2016 Jan;29(1):105-47. doi: 10.1128/CMR.00030-15. Clin Microbiol Rev. 2016. PMID: 26598386 Free PMC article.
Cited by
-
Quality improvement project to reduce length of stay for patients with urinary tract infections in an NHS hospital trust.BMJ Open Qual. 2025 Aug 4;14(3):e002998. doi: 10.1136/bmjoq-2024-002998. BMJ Open Qual. 2025. PMID: 40759528 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials